•  PROGRAM 

TELEPH.GSM

see

 

USER PROGRAMMING

 on page 18.

Should the unit indicate there is a problem with the motor pump, a message is sent to the first number. If 

there is no answer, 10 minutes later a message is sent to the second number, and so on. Three numbers 

can be set in total. The process continues for 4 times if none of the 3 users contacted sends an SMS reply 

to the unit using the phrase OK. Any subsequent problems with the pump result in the SMS notification 

process being started again.  

N.B.: It is possible that, once one of the 3 users has sent an OK message to the unit, another error mess-

age may be sent to the second user. This is due to delays caused by traffic on the telephone network and 

is outwith the control of the unit.   

TO CONFIRM RECEPTION OF THE 

SMS WARNING MESSAGE

 AND 

STOP THE SENDING OF SUBSE-

QUENT

 MESSAGES, SEND A MESSAGE FROM YOUR CELL PHONE USING THE PHRASE 

OK.

 

 

 

 

 

After confirmation,

    the 

display 

will 

show

    

Decreases 

  

  Increases

Press to

write the number

left  

  

 right

Moves the cursor

CHOICE OF 

SUBSCRIBER

WRITE THE MOBILE 

PHONE NUMBER

CONFIRMATION

Example

or 2 - 3

NUMBER

SUBSCRIBER

MOBILE

PHONE

NUMBER

Cursor 

that 

flashes

Indicates 

that the 

number 

continues 

right >

< left

Push to view 

the first, 

second 

or third 

subscriber.

Press and

wait for

OK to be

written.

MOB.        1

MOB.        1

-123456789>

 333456789

NOTIFIED

          

MOB.        1

 333-

Notifies via SMS message when the motor pump is in alarm condition

Programming the cell phone numbers of the users who are to be notified when the motor 

pump is in alarm condition

IMPORTANT NOTE

In order for a command sent via SMS to be interpreted

correctly, it is important to programme the telephone number exactly as it is 

given by the mobile telephone network, and therefore inclusive of international 

dialling code and without the first zero of the dialling code (if there is one) of 

the telephone company.

 

Ex1:   Italian number = 348123456

 

 

programme

 

     

 + 39348123456

 

Ex2:   English number = 0797123456 (leave out the 1st zero) 

 

 

 

programme      

 + 44797123456

In any case, refer to the national numbering system.

  When the SMS TO ALL PHONES INCLUDED function is used (factory setting, see page 20 of the 

technical programming manual) the SMS fault messages are sent only to the telephones programmed in 

the list of telephone numbers of the control unit. For example: an operator who starts the motor pump from 

their mobile phone, and does not have their telephone number programmed in the list of telephone num

-

bers, will NOT receive the SMS message in the event of a fault. But it will be received by the telephone 

with its number programmed in the CIM control unit following the procedure described later.

Содержание 00211143

Страница 1: ...pressure of the system constant accelerator with 2 wires connected to the control unit Controls the flow of water in the pipe Electronic pressure switch to control the pump water pressure Digital pum...

Страница 2: ...SPLAY CHANGES HOLD DOWN TO SI LENCE THE GENERAL ALARM BUZZER PRESS UNTIL THE 2 SIGNS START FLASHING TO EXCLUDE PUMP PROTECTION TO RE ACTIVATE PROTECTION PRESS AGAIN UNTIL THEY SWITCH OFF PRESSTOSTART...

Страница 3: ...iming Pump priming failure 5 Operation Clutch Engine warming Engine cooling Stop Emergency stop Stop with the Stop and Off Reset buttons Stopping failure Buzzer 6 Operation Timer Resetting of the set...

Страница 4: ...SSURE SWITCH Press to select the pump water pressure gauge FAILURE TO FILL PIPES FAULT The acceleration starts with the engine running with pump primed The motor pump reaches the redefined WORKING PRE...

Страница 5: ...if the pump has not started up after the fourth pulse It is obtained with measurement of the voltage and frequency of the battery charging alternator Disables the starter motor The priming pump start...

Страница 6: ...ng buttons the engine stops after slow deceleration Stopping can be obtained in two ways With electromagnet de energized with engine running and energized with it stopped remaining in this condition f...

Страница 7: ...display the end of work time indicator comes on The work time is set by pressing the push button lights up until the desired value appears on the DISPLAY On releasing the push button the timer automat...

Страница 8: ...th running engine 2 YES SLOW YES WITH STOP The temperature detected by the transmitter exceeds the set threshold FUEL RESERVE FUEL RESERVE Flashing FUEL FLOAT TERMINAL T Always active 5 10 NOT NOT DOE...

Страница 9: ...of the intervention delay INSUFFICIENT PUMP WATER PRESSURE INSUFFICIENT WATER PRES SURE ELECTRONIC PRESSURE SWITCH After detection of working pressure and in any case 600 after the pump started 5 YES...

Страница 10: ...OWN only for permanent magnet WHITE YELLOW ORANGE BLACK BATTERY STOP SYSTEMS SEE PAGE 11 ORANGE BLUE INDICA TOR W RESERVE ACCELERATOR YELLOW GREEN BLACK BLUE ORANGE BROWN WHITE VIOLET CABLE 1 5m BLACK...

Страница 11: ...ER and the oil PRESSURE GAUGE connect the transmitters to the respective wires of the unit then CUT and isolate the BLACK VIOLET wire WARNING IT IS NOT POSSIBLE TO MOUNT THE EMERGENCY STOP BUTTON ON A...

Страница 12: ...g pump P2 starts when the water reaches the priming probe lthe pump stops PRIMING FAILURE The pump is stopped if the priming probe does not sense the presence of water within 240 sec To connect PUMP P...

Страница 13: ...hased from a telephone provider on any contract the PIN needs to be disabled To do this it is necessary to insert the SIM in a normal private use cell phone then enter the PIN supplied by the provider...

Страница 14: ...ght left Push to view the first second or third subscriber Press and wait for OK to be written MOB 1 MOB 1 123456789 333456789 NOTIFIED MOB 1 333 Notifies via SMS message when the motor pump is in ala...

Страница 15: ...ion exclusion After the switch off command the following is displayed After the command to delete switching off the following is displayed After the command the following is displayed After the comman...

Страница 16: ...stopped STOP MOTOR PUMP START WATER PRESSURE HOURS OF OPERATION FUEL FAULT The fuel fault depends on any change in the fuel level in the motor pump tank when the engine is stopped The check up is ena...

Страница 17: ...CONTROL UNIT IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING CONDITIONS Where the environmental temperature is outside the limits indicated in the Technical Data Where the air pressure and temperature...

Страница 18: ...tes Decreases Increases Decreases Increases Set the engine revolutions read on the portable tachometer Press and wait for OK to be written Press and wait for OK to be written Press and wait for OK to...

Страница 19: ...ming pump yellow blue pump clutch white yellow 3A 40A 3A 3A 3A 3A Temperature range 10 60 C MODEM B1 B3 B5 B7 B8 B20 FDD LTE B1 B5 B8 WCDMA B3 B8 GSM Hour meter 4 digits Engine oil pressure gauge 0 9...

Страница 20: ...Flow switch FAP 200 00500312 ORDERING DATA ACCESSORIES SUPPPLIED Type CIM 137 4G CODE 00211143 CIM 137 4GW CODE 00211151 PRE WIRED CONNECTOR CIM 130 1 6 7 CODE 70804397 TRANSMITTER TYPE TPA 200 CODE 7...

Отзывы: