elco ELM-4D1P Скачать руководство пользователя страница 5

ELM-4D1P 

instruction manual

IM443-U v0.7 

pag. 5

 

DESCRIPTION FRONT PANEL– OPERATORS

 

 

 

 

 

 

 

 

 

 

 

 

VA 

V

L-L

 

 

 

 

LEGEND:

 

A

:        push-button for the visualization of electrical parameters of three-phase system with the corresponding LED 

indication. In modality programming (SETUP) it’s used to confirm the parameter set. 

B

:        push-button for the selection of the electrical parameter to be displayed on display 

F

. In modality programming 

(SETUP) it’s used to increase the value of the parameters to set. 

C

push-button   for   the   selection   of   the   electrical   parameter   to   be   displayed   on   display  

G

.   In   modality 

programming (SETUP) it’s used to reduce the value of the parameters to set. 

D

:        LED bar for the indication of the electrical parameter displayed on display 

F

E

:        LED bar for the indication of the electrical parameter displayed on display 

G

F

:        3 displays for the visualization of electrical measures of every phase. 

When 

Σ

LED is ON, only the main display will be active showing the three-phase system value of the 

electrical measure selected. 
LED 

and 

show the eventual multiplying factor (k = kilo=x 1.000, M =Mega= x 1.000.000) 

Using the 

key the display indicates also the values of the active and reactive energy counters. 

Using the 

and 

keys the display indicates the maximum and average values. 

G

:       display for the visualization of the electrical measure indicated in LED 

(energy counters excluded). 

The voltage values are referred to the three-phase system. 
The 

LED displays the reading in kilo (x 1000). 

Using the 

key the display indicates the type of the energy displayed. 

Using the 

and 

keys the displays indicate the type of the value: average or maximum. 

A+C

:when pressing simultaneously the instrument pass to the following menu: 

- instrument programming (SETUP) 
- energy counters and peak values deleting (RESET) 
- digital outputs programming (SET  DO1

SET  DO  2) 

- analog output programming (SET  AN   OUT) 
- hour counter programming (HR_) 
- I/O diagnostic page 

A+B

:when pressing simultaneously the instrument pass to the visualization of average and maximum values 

stored. 

 

MENU OF INSTRUMENT PROGRAMMING 

(

SETUP

)

 

To enter in SETUP it’s necessary to press at the same time 

and 

keys, on the 

display will appear the message 

SeTUp. Pressing the 

key on the 

display will appear the message SET   that will  remain always displayed during 

the set of each parameter to highlight the setup phase in running. 
The set values will be keep also in absence of auxiliary power supply. 

Содержание ELM-4D1P

Страница 1: ...485 and with analog output OPTIONS Power Supply 20 60 Vac 24 72 Vcc C1 Power Supply 85 230 Vac 90 250 Vcc C2 Insulated current inputs T MEASURED PARAMETERS parameters unit of measurement initial ident...

Страница 2: ...Vac dc version Terminals Power Supply Terminals Power Supply Terminals Power Supply 19 20 0 110V 100 125Vac 50 60Hz 19 21 0 230V 220 240Vac 50 60Hz 19 23 0 400V 380 415Vac 50 60Hz 19 21 20 60Vac 24 7...

Страница 3: ...WIRING DIAGRAMS W ELM 4D1P instruction manual IM443 U v0 7 pag 3...

Страница 4: ...internalCT S1 I1 S2 auxiliary power supply S1 I2 S2 S1 ELM I3 S2 VL1 VL2 VL3 N with Ineutral option In VL1 VL2 VL3 N L1 S1 L2 P1 L3 S1 S2 L1 L2 L3 S1 S2 N P1 P2 P1 P2 CT connection to Voltage insertio...

Страница 5: ...lay indicates also the values of the active and reactive energy counters Using the A and B keys the display indicates the maximum and average values G display for the visualization of the electrical m...

Страница 6: ...ynchronism 50 type 60 version with digital output seT PUL SE 10 0 kW kVAr pulse Set pulse weight 01 0 kW kVAr pulse 0 10 kW kVAr pulse 0 01 kW kVAr pulse version with digital output seT TPL Increase f...

Страница 7: ...of the CT rate will be possible to set this value example with CT 1000 5the value will be 200 Pressing the A key confirm and go away with the next setting Programming of the average time seT AVG T Aft...

Страница 8: ...e password is wrong the message PASS ERR will appear on F display and the instrument go back to the measures visualization To input the password when required by the instrument at the enter of the set...

Страница 9: ...tput will function as alarm verifying that the maximum value of the single phases doesn t exceed the maximum threshold set ALR HI and that the minimum value of the single phases doesn t come down the...

Страница 10: ...the set SET THE HIGH AND THE LOW THRESHOLDS On F display will appear the message ALR Hi with the high threshold value confirming with the A key on the same display will appear the message ALR LO with...

Страница 11: ...ing the C key the message SET AN OUT will appear on the F display To accede to the menu programming press the A key the message SET will appear on the G display on the F display and on D led bar will...

Страница 12: ...key to select the parameter and the A key to confirm it SET THE THRESHOLD Subsequently it s necessary to set the threshold using the B to increase and C to decrease keys Confirm with A key I O INFO P...

Страница 13: ...the measures appear on the L1 display Visualization section 2 At the same way of the section 1 press the C button to select the parameter that can be displayed and indicated from E LED The voltage va...

Страница 14: ...er maximum three phase powers max maxD avg I L1 max avg I L2 max avg I L3 max avg I N max avg phase and neutral currents maximum of average phase and neutral currents max demand max maxD avg W max avg...

Страница 15: ...electrically disturbed it is suggested to use 100 120ohm 1 2W resistors placed between the common of the RS485 outlet and the shielded cable For other information on the serial line it s better to se...

Страница 16: ...auto consumption 0 5VA INPUTS OUTPUTS digital outputs Two outputs with common optomos 12 230Vac dc max 150mA insulation 3kV for 60 seconds Pulse Function Weight programmable 0 01 0 1 1 10 kWh pulse P...