63
Errors
If the facility is shut down, then a
warning signal ( ) and a blinking
error code is displayed on screen. The
cause of the shutdown must first be
remediated, before one can proceed
with a reset of the THISION S PLUS
boiler. The attached to list shows
possible reasons for shutdowns and
the possible cause of the malfunction.
Code Description of the error
0
No error
10
Outdoor temperature sensor error
20
Boiler temperature 1 - sensor defect
26
Joint inlet temperature sensor error
28
Smoke/ waste gas temperature sensor error
30
Inlet temperature 1 - sensor defect
32
Inlet temperature 2 - sensor defect
38
Inlet temperature of pre-controller sensor error
40
Return temperature 1 - sensor defect
46
Return temperature cascade sensor error
47
Joint return temperature sensor error
50
Drinking water temperature 1 sensor error
52
Drinking water temperature 2 sensor error
54
Drinking water pre-controller sensor error
57
Drinking water circulation temperature sensor error
60
Room temperature 1 - sensor defect
65
Room temperature 2 - sensor defect
70
Buffer tank temperature 1 sensor error
71
Buffer tank temperature 2 sensor error
72
Buffer tank temperature 3 sensor error
73
Collector temperature 1 sensor error
74
Collector temperature 2 sensor error
82
LPB address collision
83
BSB wire short-circuit
84
BSB address collision
85
BSB radio communications error
91
EEPROM error with locking information
98
Expansion module 1 error (combined error)
99
Expansion module 2 error (combined error)
100
Two master clocks (LPB)
102
Master clock without power reserve (LPB)
103
Communications error
105
Maintenance report
109
Boiler temperature monitoring
110
Safety temperature limiter defect shutdown
111
Temperature monitor shutdown
119
Safety thermostat of burner door interrupted
121
Flow temperature 1 (heating circuit 1) monitoring
122
Flow temperature 2 (heating circuit 2) monitoring
125
Pump monitoring error
126
Drinking water filling monitoring
127
Anti-legionella temperature not reached
128
Flame failure during operations
129
Fan failure or air pressure monitor error
130
Limit value of waste gas temperature exceeded
131
Burner malfunction
132
Gas pressure monitor or air pressure monitor error
133
No flame during safety interval
146
Configuration error group report
151
Internal error
152
Parameterization error
153
Facility manually locked
160
Fan error
162
Air pressure monitor error - does not close
164
Heating circuit flow switch error
166
Air pressure monitor error - does not open
171
Alarm contact H1 or H4 active
172
Alarm contact H2 (EM1, EM2 or EM3) or H5 active
173
Alarm contact H6 active
174
Alarm contact H3 or H7 active
178
Temperature monitor heating circuit 1