Collector assembly
Manifold assembly
Vertical installation
(Sloped roof type A;
Flat roof types C and E)
•
Start with a basic module with sensor
connector (the sensor connector is
located on the left side of the manifold
and is not visible here). Slide the pre-
assembled manifold into the fasteners
and clamp it down by tightening the
bolts. Tightening torque: 25 Nm.
•
Slide the expansion modules into the
fasteners and the manifold intercon-
necting plate. Push the manifolds
together until they butt up against
each other. Clamp the manifolds by
tightening the bolts. Tightening
torque: 25 Nm.
•
Interconnect the manifolds' prein-
stalled hydraulic expansion fittings.
Use a counter-wrench when mount-
ing the fittings! Do not twist the man-
ifold tubing.
Horizontal mounting (sloped roof
type B; façade type D)
•
Slide the prepared manifold into the
fasteners and hook it onto the mount-
ing bracket that prevents the manifold
from slipping. Make sure it is com-
pletely hooked in. Clamp the manifold
by tightening the bolts.
Tightening torque: 25 Nm
•
Slide the next module into the fasten-
ers and the manifold interconnecting
plate. Push the manifolds together
until they butt up against each other.
Clamp the manifolds by tightening the
bolts.
Tightening torque: 25 Nm
•
Interconnect the manifolds' prein-
stalled hydraulic expansion fittings.
Use a counter-wrench when mount-
ing the fittings! Do not twist the man-
ifold tubing.
Содержание AURON B 15 DF
Страница 1: ...Operating manual For professional installers AURON with EDF evacuated tubes 04 2013 Art Nr 12 054 556...
Страница 40: ...40 Collector assembly Fa ade summary for type D 13 21 4 1 6 2 3 5 15 10 11 7 14 25...
Страница 52: ...52...
Страница 55: ...55 Troubleshooting problems and remedies Antifrogen SOL HT Antifrogen SOL HT and vent...
Страница 62: ...62...
Страница 63: ...63...