Installing the mounting rack
Flat roof type E: Outdoor / flat roof assembly using mounting
rack with no adjustable angle of inclination.
Install the mounting rails
•
Fasten the mounting rails to the con-
crete pavers using appropriate lag
bolts (socket size 13 mm), washers
and anchors.
•
Hanger bolts and appropriately thick
concrete pavers can also be used to
fasten the mounting rails to gain more
clearance to the roof covering.
•
Fasten the rails to the hanger bolt
connecting bracket from below. Be
sure to observe the minimum required
projections to fasten the mounting
brackets for the manifolds and bottom
rails.
Install fasteners
•
Insert a fastener for the manifold into
the mounting rail and position it so
that it is flush with the upper edge of
the mounting rail. Press on the bolt to
snap the fastener into place.
•
Insert the fastener for the bottom rail
flush with the opposite end of the
mounting rail and line it up. Press on
the bolt to snap the fastener into
place. To keep the fastener in place,
hand tighten the nut by two or three
turns; do not tighten permanently yet.
Inspection
After assembling the fasteners, double
check their position. All fasteners shall
be lined up at the same level. Rails
shall be perfectly parallel.
Содержание AURON B 15 DF
Страница 1: ...Operating manual For professional installers AURON with EDF evacuated tubes 04 2013 Art Nr 12 054 556...
Страница 40: ...40 Collector assembly Fa ade summary for type D 13 21 4 1 6 2 3 5 15 10 11 7 14 25...
Страница 52: ...52...
Страница 55: ...55 Troubleshooting problems and remedies Antifrogen SOL HT Antifrogen SOL HT and vent...
Страница 62: ...62...
Страница 63: ...63...