background image

Tensione CA (Autorange tranne per gamma 400mV) 

Gamma

 

di

 

misurazione

 

Risoluzione

 

Precisione

 

400.0mV

  

0.1mV

 

±1.5%of

 

rdg

 

±15dgts

 

4.000V

 

1.0mV

 

40.00V

 

10mV

 

±

 

1.0%

 

of

 

rdg

 

±

 

4dgts

  

 

100.0V

 

100mV

 

±1.5%

 

of

 

rdg

 

±

 

4dgts

  

250V

 

1V

 

±2%

 

of

 

rdg

 

±

 

4dgts

  

Impedenza d'ingresso: 10M

Gamma di frequenza: da 50 a 400Hz

 

Massimo valore d’Ingresso: 250 VCC o 250VCA rms 
 
Corrente CC (Autorange) 

Gamma

 

di

 

misurazione

 

Risoluzione

 

Precisione

 

400.0uA

 

0.1uA

 

4000uA

 

1uA

 

40.00mA

 

10uA

 

±

 

1.0%

 

of

 

rdg

 

±

 

2

 

dgts

 

400.0mA

 

100uA

 

±

 

1.2%

 

of

 

rdg

 

±

 

2

 

dgts

 

10.00A

 

10mA

 

±

 

2.0%

 

of

 

rdg

 

±

 

5

 

dgts

 

Protezione da sovraccarico: Fusibili 500mA/250V e 10A/250V 
Ingresso massimo: 400mA DC o 400mA AC rms per gamme di misurazione uA /mA, 
10ACC o CA rms nella gamma 10A. 
Corrente AC  (Ricerca automatica campo d’azione per uA/mA) 

Gamma

 

di

 

misurazione

 

Risoluzione

 

Precisione

 

400.0uA

 

0.1uA

 

4000uA

 

1uA

 

40.00mA

 

10uA

 

±

 

1.2%

 

of

 

rdg

 

±

 

2

 

dgts

 

400.0mA

 

100uA

 

±

 

1.5%

 

of

 

rdg

 

±

 

2

 

dgts

 

10.00A

 

10mA

 

±

 

2.0%

 

of

 

rdg

 

±

 

5

 

dgts

 

Protezione da sovraccarico: 2,8V Fusibili da 500mA/250V e 10A/250V 
AC Risposta: 50 Hz a 400 Hz 
Ingresso massimo: 400mA CC o 400mA CA rms per le gamme uA / mA, 10A CC o CA 
rms per le gamme 10A.  
• Resistenza:  (Autorange) 

Gamma

 

di

 

misurazione

 

Risoluzione

 

Precisione

 

400.0

Ω 

0.1uA

 

4000

 Ω 

1uA

 

40.00

 Ω 

10uA

 

±

 

1.2%

 

of

 

rdg

 

±

 

2

 

dgts

 

400.0

 Ω 

100uA

 

±

 

1.5%

 

of

 

rdg

 

±

 

2

 

dgts

 

10.00

 Ω 

10mA

 

±

 

2.0%

 

of

 

rdg

 

±

 

5

 

dgts

 

Protezione da sovraccarico: 15 secondi massimo 250V CC o 250V CA rms, per tutte le 
gamme. 
Massima tensione a circuito aperto: 2,8 V

 

• Capacità: (Autorange) 

Gamma

 

di

 

misurazione

 

Risoluzione

 

Precisione

 

50.00nF

 

10pF

 

±

 

5.0%

 

of

 

rdg

 

±

 

20

 

dgts

 

500.0nF

 

0.1nF

 

5.000uF

 

1nF

 

50.00uF

 

10nF

 

±

 

3.0%

 

of

 

rdg

 

±

 

5

 

dgts

 

100.0uF

 

0.1uF

 

±

 

4.0%

 

of

 

rdg

 

±

 

5

 

dgts

 

Protezione

 

ingresso:

 

250V

 

CC

 

o

 

250V

 

CA

 

rms

 

 
 

Frequenza:

 

(Autorange)

 

Gamma

 

di

 

misurazione

 

Risoluzione

 

Precisione

 

5.000Hz

 

0.001Hz

 

50.00Hz

 

0.01Hz

 

500.0Hz

 

0.1Hz

 

5.000KHz

 

1Hz

 

50.00KHz

 

10Hz

 

500.0KHz

 

100Hz

 

±

 

1.2%

 

of

 

rdg

 

±

 

3

 

dgts

 

10.00MHz

 

1KHz

 

±

 

1.5%

 

of

 

rdg

 

±

 

4

 

dgts

 

Sensibilità: > 0.5V RMS mentre 

 1 MHz; 

Sensibilità: > 3V RMS mentre  > 1MHz; 
Protezione di ingresso: 250V DC o 250V AC rms. 
Controllo diodo e continuità 
Diodo: Controllare che la corrente sia 1.4mA e la tensione del circuito aperto sia 2.8V. 
Continuità: Il rilevatore acustico interno suonerà se c’è continuità. (R < 5

Protezione da sovraccarico: massimo 250 V cc oppure  250 V AC rms. 

 
 
 
 
 
 
 
 
 
 
 

ELCART DISTRIBUTION SPA  via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY

Tel. ++39(0)2/25.11.73.10 Fax ++39(0)2/25.11.76.10 sito internet:  www.elcart.com    e-mail: [email protected]

La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.

Содержание Nimex NI-8002

Страница 1: ...C Current 6 8 Measuring AC Current 6 9 Measuring Capacitance 6 10 Measuring Frequence 6 11 Measuring Resistance 6 12 Measuring Diode 6 13 Audible Continuity Test 6 14 Non contact AC Voltage Test NCV 7...

Страница 2: ...measurement and Audible Continuity Diode Temperature test 2 Safety Instructions This meter has been designed for safe use but must be operated with caution The rules listed below must be carefully fol...

Страница 3: ...n to select AC or DC measurement when in Voltage ranges 15 REL button The relative measurement feature allows you to make measurements relative to a stored reference value A reference voltage current...

Страница 4: ...icrophone Electric condenser microphone 5 2 Light Measuring Range 4000 40 000Lux 40 000Lux range reading xl 0 Overrate Display Highest digit of OL is displayed Accuracy 5 rdg 10 dgts calibrated to sta...

Страница 5: ...2 dgts 10 00 10mA 2 0 of rdg 5 dgts Overload Protection 15 seconds maximum 250V DC or 250V AC rms on all ranges Maximum open circuit voltage 2 8V Capacitance Auto ranging Range Resolution Accuracy 50...

Страница 6: ...the photo detector from the light source Spectral sensitivity characteristic To the detector the applied photo diode with filters makes the spectral sensitivity characteristic almost meet CIE Internat...

Страница 7: ...DC set the function switch to the yellow 10A position and insert the red test lead banana plug into the 10A jack Press the MODE button to indicate DC on the display Remove power from the circuit unde...

Страница 8: ...Voltage Test NCV Set the function switch to the ON position Remove the meter and face the NCV detector to ACV source If source voltage in 200 1000V the NCV indicate lamp will light 7 Maintenance Batte...

Страница 9: ...CA 6 7 Misurazione Corrente CC 6 8 Misurazione Corrente CA 6 9 Misurazione Capacit 6 10 Misurazione Frequenza 6 11 Misurazione Resistenza 6 12 Misurazione Diodi 6 13 Test Continuit 6 14 Non contact A...

Страница 10: ...misura di resistenza e continuit diodo e prove di temperatura 2 Informazioni di sicurezza Questo strumento stato progettato per un utilizzo sicuro ma deve essere gestito con cautela Le norme sotto ind...

Страница 11: ...re DC quando si agisce nei campi di azione A mA uA e 14 Pulsante RANGE Pulsante per la selezione di misurazione AC oppure DC quando e presente tensione per i campi di azione di 15 Pulsante REL La funz...

Страница 12: ...condensatore elettrico 5 2 Luce Gamma di misurazione 4000 40 000 Lux 40 000 Lux di gamma lettura x 10 Indicatore Sovraccarico Viene visualizzato il simbolo OL Precisione 5 rdg 10 cifre calibrato per...

Страница 13: ...of rdg 2 dgts 400 0 100uA 1 5 of rdg 2 dgts 10 00 10mA 2 0 of rdg 5 dgts Protezione da sovraccarico 15 secondi massimo 250V CC o 250V CA rms per tutte le gamme Massima tensione a circuito aperto 2 8...

Страница 14: ...d ingresso troppo forte e dovete selezionare una gamma di misurazione pi alta Quando la misurazione stata completata Togliere il lettore ottico dalla sorgente luminosa Caratteristica di sensibilit sp...

Страница 15: ...ollegare i puntali in serie al circuito da misurare Alimentare il circuito Leggere il valore sul display 6 8 Misurazione corrente CA Inserire il puntale nero nel terminale COM e il puntale rosso nel t...

Страница 16: ...ima di tentare di aprire il vano assicurarsi che i puntali siano scollegati dal circuito di misura per evitare scosse elettriche Sostituire il fusibile solo con fusibili con le stesse caratteristiche...