background image

6-4 Measuring Temperature  
Temperature Measurement for outdoor:  
• Set the function switch to the green "0.1°C" position or "1°C" position.  
•Then the display will show the environment temperature reading value °C 
directly.  
• Insert the black plug of temperature probe the COM jack and red plug to the 
"V/Hz%/

/CAP/°C" jack. 

 •Touch the end of the temperature sensor to the area or surface of the object 
to be measured. The display will show the temperature reading value °C 
directly.  
6-5 Measuring DC Voltage  
•Insert the black test lead banana to the COM jack and red test lead banana to 
the "V/Hz%/

/CAP/°C" jack.  

•Set the function switch to the green at DCV ranges to be used and connect 
test leads connect test leads across the source or load under measurement.  
•Set the function switch at DCmV ranges to be used connect test leads 
connect test leads across the source or load under measurement.  
•Read LCD display. The polarity of red connection will be indicated when 
making a DC measurement. 
• Press the Hz% button to indicate "Hz".  
• Read the frequency in the display. s Press the Hz% button again to indicate 
"%".  
• Read the % of duty cycle in the display.  
6-6 Measuring AC Voltage 
• Insert the black test lead banana to the COM jack and red test lead banana 
to the "V/Hz%/0/

/CAP/°C" jack.  

•Set the function switch to the green at AC ranges to be used and connect test 
leads connect test leads across the source or load under measurement.  
•Read LCD display. The polarity of red connection will be indicated when 
making a AC measurement.  
•Press the Hz% button to indicate "Hz". 
•Read the frequency in the display. Press the Hz% button again to indicate 
"%.  
•Read the % of duty cycle in the display.  
6-7 Measuring DC Current  
• Insert the black test lead banana plug into the negative COM jack, and the 
red test lead banana plug into the "uA/mA"or "10A" jack.  

• For current measurements up to 4000uA DC, set the function switch to the 
µA position and insert the red test lead banana plug into the uA/mA jack.  
•For current measurements up to 400mA DC, set the function switch to the 
mA position and insert the red test lead banana plug into the µA/mA jack.  
•For current measurements up to 10A DC, set the function switch to the yellow 
10A position and insert the red test lead banana plug into the 10A jack.  
•Press the MODE button to indicate "DC" on the display.  
•Remove power from the circuit under test, then open up the circuit at the 
point where you wish to measure current. 
•Touch the black test probe tip to the negative side of the circuit. Touch the 
red test probe tip to the positive side of the circuit.  
•Apply power to the circuit.  
•Read the current in the display.  
6-8 Measuring AC Current 
•Insert the black test lead banana plug into the negative COM jack. and the 
red test lead banana plug into the "uA/mA"or "10A" jack.  
•For current measurements up to 4000uA AC, set the function switch to the uA 
position and insert the red test lead banana plug into the uA/mA jack.  
•For current measurements up to 400mA AC, set the function switch to the mA 
position and insert the red test lead banana plug into the uA/mA jack  
•For current measurements up to 10A AC, set the function switch to the yellow 
OA position and insert the red test lead banana plug into the 10A jack 
•Press the MODE button to indicate "AC" on the display.  
•Remove power from the circuit under test, then open up the circuit at the 
point where you wish to measure current.  
•Touch the black test probe tip to the neutral side of the circuit.  
•Touch the red test probe tip to the "hot" side of the circuit.  
•Apply power to the circuit. -Read the current in the display.  
•Press and hold the Hz% button to indicate "Hz".  
•Read the frequency in the display.  
•Momentarily press the Hz% button again to indicate "%".  
•Read the % duty cycle in the display.  
•Press and hold the Hz% button to return to current measurement.  
6-9 Measuring Capacitance  
•Set the function switch to the green CAP position.  
•Insert the black test lead banana plug into the negative COM jack and the red 
test lead banana plug into the "V/Hz%/

/CAP/°C" jack. (If value is no zero in 

the display. Press the REL button to zero) 

ELCART DISTRIBUTION SPA  via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY

Tel. ++39(0)2/25.11.73.10 Fax ++39(0)2/25.11.76.10 sito internet:  www.elcart.com    e-mail: [email protected]

La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.

Содержание Nimex NI-8002

Страница 1: ...C Current 6 8 Measuring AC Current 6 9 Measuring Capacitance 6 10 Measuring Frequence 6 11 Measuring Resistance 6 12 Measuring Diode 6 13 Audible Continuity Test 6 14 Non contact AC Voltage Test NCV 7...

Страница 2: ...measurement and Audible Continuity Diode Temperature test 2 Safety Instructions This meter has been designed for safe use but must be operated with caution The rules listed below must be carefully fol...

Страница 3: ...n to select AC or DC measurement when in Voltage ranges 15 REL button The relative measurement feature allows you to make measurements relative to a stored reference value A reference voltage current...

Страница 4: ...icrophone Electric condenser microphone 5 2 Light Measuring Range 4000 40 000Lux 40 000Lux range reading xl 0 Overrate Display Highest digit of OL is displayed Accuracy 5 rdg 10 dgts calibrated to sta...

Страница 5: ...2 dgts 10 00 10mA 2 0 of rdg 5 dgts Overload Protection 15 seconds maximum 250V DC or 250V AC rms on all ranges Maximum open circuit voltage 2 8V Capacitance Auto ranging Range Resolution Accuracy 50...

Страница 6: ...the photo detector from the light source Spectral sensitivity characteristic To the detector the applied photo diode with filters makes the spectral sensitivity characteristic almost meet CIE Internat...

Страница 7: ...DC set the function switch to the yellow 10A position and insert the red test lead banana plug into the 10A jack Press the MODE button to indicate DC on the display Remove power from the circuit unde...

Страница 8: ...Voltage Test NCV Set the function switch to the ON position Remove the meter and face the NCV detector to ACV source If source voltage in 200 1000V the NCV indicate lamp will light 7 Maintenance Batte...

Страница 9: ...CA 6 7 Misurazione Corrente CC 6 8 Misurazione Corrente CA 6 9 Misurazione Capacit 6 10 Misurazione Frequenza 6 11 Misurazione Resistenza 6 12 Misurazione Diodi 6 13 Test Continuit 6 14 Non contact A...

Страница 10: ...misura di resistenza e continuit diodo e prove di temperatura 2 Informazioni di sicurezza Questo strumento stato progettato per un utilizzo sicuro ma deve essere gestito con cautela Le norme sotto ind...

Страница 11: ...re DC quando si agisce nei campi di azione A mA uA e 14 Pulsante RANGE Pulsante per la selezione di misurazione AC oppure DC quando e presente tensione per i campi di azione di 15 Pulsante REL La funz...

Страница 12: ...condensatore elettrico 5 2 Luce Gamma di misurazione 4000 40 000 Lux 40 000 Lux di gamma lettura x 10 Indicatore Sovraccarico Viene visualizzato il simbolo OL Precisione 5 rdg 10 cifre calibrato per...

Страница 13: ...of rdg 2 dgts 400 0 100uA 1 5 of rdg 2 dgts 10 00 10mA 2 0 of rdg 5 dgts Protezione da sovraccarico 15 secondi massimo 250V CC o 250V CA rms per tutte le gamme Massima tensione a circuito aperto 2 8...

Страница 14: ...d ingresso troppo forte e dovete selezionare una gamma di misurazione pi alta Quando la misurazione stata completata Togliere il lettore ottico dalla sorgente luminosa Caratteristica di sensibilit sp...

Страница 15: ...ollegare i puntali in serie al circuito da misurare Alimentare il circuito Leggere il valore sul display 6 8 Misurazione corrente CA Inserire il puntale nero nel terminale COM e il puntale rosso nel t...

Страница 16: ...ima di tentare di aprire il vano assicurarsi che i puntali siano scollegati dal circuito di misura per evitare scosse elettriche Sostituire il fusibile solo con fusibili con le stesse caratteristiche...