background image

3. Panel description 

 

 

1. Humidity & Temperature 
Humidity sensor ad semiconductor sensor inside for indoor. 
2. LCD Display 
3 4/5 digits LCD display 
3. Function switch 
4. V / Hz% / 

 / CAP / °C input jack 

5. COM input jack 
6. µA / mA input jack 
7- 10A input jack 
8. Microphone 
Electric condenser microphone inside.  
9. Photo Detector  
Long life silicon photo diode inside.  

10. Hz/% button  
The button at AC/DC Voltage measurement and AC/DC Current measurement 
and Hz% measurement. Function is availability.  
11 . HOLD button  
The HOLD function allows the meter to "freeze" a measurement for later 
reference. Press the HOLD button to "freeze" the reading on the indicator. The 
"HOLD" message will be appear in the display.  
1 2. BACKLIGHT button  
Press the backlight button for LCD light, again Press the backlight button to 
exit light mode.  
13. MODE button  
The button to select AC or DC measurement when in A, mA, uA, and 

,  ,  

ranges.  
14. RANGE button  
The button to select AC or DC measurement when in Voltage, 

 ranges.  

15. REL button  
•The relative measurement feature allows you to make measurements relative 
to a stored reference value. A reference voltage, current, Capacitor, etc. can 
be stored and measurements made in comparison to that value. The 
displayed value is the difference between the reference value and the 
measured value. 
• Perform the measurement as described in the operating instructions.  
• Press the REL button to store the reading in the display and the "REL" 
indicator will appear on the display.  
•The display will now indicate the difference between the stored value and the 
measured value.  
•Press the REL button to exit the relative mode.  
16. NCV indicate lamp 
 
 
 
 
 
 
 
 
 
 

ELCART DISTRIBUTION SPA  via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY

Tel. ++39(0)2/25.11.73.10 Fax ++39(0)2/25.11.76.10 sito internet:  www.elcart.com    e-mail: [email protected]

La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.

Содержание Nimex NI-8002

Страница 1: ...C Current 6 8 Measuring AC Current 6 9 Measuring Capacitance 6 10 Measuring Frequence 6 11 Measuring Resistance 6 12 Measuring Diode 6 13 Audible Continuity Test 6 14 Non contact AC Voltage Test NCV 7...

Страница 2: ...measurement and Audible Continuity Diode Temperature test 2 Safety Instructions This meter has been designed for safe use but must be operated with caution The rules listed below must be carefully fol...

Страница 3: ...n to select AC or DC measurement when in Voltage ranges 15 REL button The relative measurement feature allows you to make measurements relative to a stored reference value A reference voltage current...

Страница 4: ...icrophone Electric condenser microphone 5 2 Light Measuring Range 4000 40 000Lux 40 000Lux range reading xl 0 Overrate Display Highest digit of OL is displayed Accuracy 5 rdg 10 dgts calibrated to sta...

Страница 5: ...2 dgts 10 00 10mA 2 0 of rdg 5 dgts Overload Protection 15 seconds maximum 250V DC or 250V AC rms on all ranges Maximum open circuit voltage 2 8V Capacitance Auto ranging Range Resolution Accuracy 50...

Страница 6: ...the photo detector from the light source Spectral sensitivity characteristic To the detector the applied photo diode with filters makes the spectral sensitivity characteristic almost meet CIE Internat...

Страница 7: ...DC set the function switch to the yellow 10A position and insert the red test lead banana plug into the 10A jack Press the MODE button to indicate DC on the display Remove power from the circuit unde...

Страница 8: ...Voltage Test NCV Set the function switch to the ON position Remove the meter and face the NCV detector to ACV source If source voltage in 200 1000V the NCV indicate lamp will light 7 Maintenance Batte...

Страница 9: ...CA 6 7 Misurazione Corrente CC 6 8 Misurazione Corrente CA 6 9 Misurazione Capacit 6 10 Misurazione Frequenza 6 11 Misurazione Resistenza 6 12 Misurazione Diodi 6 13 Test Continuit 6 14 Non contact A...

Страница 10: ...misura di resistenza e continuit diodo e prove di temperatura 2 Informazioni di sicurezza Questo strumento stato progettato per un utilizzo sicuro ma deve essere gestito con cautela Le norme sotto ind...

Страница 11: ...re DC quando si agisce nei campi di azione A mA uA e 14 Pulsante RANGE Pulsante per la selezione di misurazione AC oppure DC quando e presente tensione per i campi di azione di 15 Pulsante REL La funz...

Страница 12: ...condensatore elettrico 5 2 Luce Gamma di misurazione 4000 40 000 Lux 40 000 Lux di gamma lettura x 10 Indicatore Sovraccarico Viene visualizzato il simbolo OL Precisione 5 rdg 10 cifre calibrato per...

Страница 13: ...of rdg 2 dgts 400 0 100uA 1 5 of rdg 2 dgts 10 00 10mA 2 0 of rdg 5 dgts Protezione da sovraccarico 15 secondi massimo 250V CC o 250V CA rms per tutte le gamme Massima tensione a circuito aperto 2 8...

Страница 14: ...d ingresso troppo forte e dovete selezionare una gamma di misurazione pi alta Quando la misurazione stata completata Togliere il lettore ottico dalla sorgente luminosa Caratteristica di sensibilit sp...

Страница 15: ...ollegare i puntali in serie al circuito da misurare Alimentare il circuito Leggere il valore sul display 6 8 Misurazione corrente CA Inserire il puntale nero nel terminale COM e il puntale rosso nel t...

Страница 16: ...ima di tentare di aprire il vano assicurarsi che i puntali siano scollegati dal circuito di misura per evitare scosse elettriche Sostituire il fusibile solo con fusibili con le stesse caratteristiche...

Отзывы: