13
ELATION DTW BAR 1000
S Y S T E M M E N U
Features are subject to change without any prior written notice.
MENU
OPTIONS / VALUES
(Default Settings in
BOLD
)
DESCRIPTION
DMX MODE
ADDR:xxx
CH:xx
ADDR:
001
- 512
CH:
01
, 02, 03, 05, 06, 07,
10, 12, 15, 20, 36, 41, 45, 72
Set DMX Address.
Set DMX Channel Mode.
CH 20 & CH 72 Added with V1.10
SLAVE
M O D E
Set unit to Slave Mode
AUTO RUN
FQN:xx
FQN:
01
-99
Set the number of times each internal macro will
repeat before moving to the next macro
01STATIC
-
15FLOW1
01
-15
Select Internal Program Macro
See
PROGRAM MACROS
for more details
DimCurve
Standard
, Stage, TV, Architec, Theatre
Set desired Dimming Curve
Flip
ON,
OFF
Set starting LED
See FLIP Section for more details
NO DMX
Hold
, Blackout, Program
Define how fixture reacts when NO DMX signal present
Manual
WW
000
-255 CW
000
-255 A
000
-255 STR:
00
-99
Set Warm White, Cool White, Amber,
and Strobe Values manually
Macros
00
-07
Select Internal Color Macro
See
COLOR MACROS
for more details
Whitebal
WW000-
255
CW000-
255
A000-
255
Adjust White Balance for each LED
NOTE: Reset to Default does NOT change these values
Net Set
Fix ID
Fix ID
Ser PIN
Ser PIN
Pass=
000
Enter Passcode
050
to access
IP Address and Universe Network Menus
Fix ID
IP Addr
000.000
000.000
Set fixture IP Address
Fix ID
MaskAddr
255.000
000.000
Set fixture Sub Net Mask Address
Fix ID
Universe
000
Set fixture Universe
Net Set
Pro Set
K - Net,
ArtNet
Set Protocol (Kling-Net or ArtNet)
Net Set
Net Swi
ON,
OFF
Set Ethernet Switch
TempUnit
F
, °C
Set Temperature Display Value to Celsius / Fahrenheit
Temp
XXX
Displays Fixture Temperature
Colortem
CTL:XXXX (1600-2500K)
CTH:XXXX (2500-6500K)
Set Dynamic DIM to WARM Control Range
CTL (Color Temp Low) CTH (Color Temp High)
Added with V1.10
Default
OFF
, ON
Reset fixture to factory default settings