29
DMX CHANNEL MODE
VALUE
FUNCTION
1
CH
2
CH
3
CH
5
CH
6
CH
7
CH
10
CH
12
CH
15
CH
36
CH
41
CH
45
CH
20
CH
SAME AS V1.02
18
CTH (CONTROL TEMP HIGH)
126-130
5,000K
131-135
5,100K
136-140
5,200K
141-145
5,300K
146-150
5,400K
151-155
5,500K
156-160
5,600K
161-165
5,700K
166-170
5,800K
171-175
5,900K
176-180
6,000K
181-185
6,100K
186-190
6,200K
191-195
6,300K
196-200
6,400K
201-255
6,500K
19
MAXIMUM OUTPUT LIMITER
(See Notes Below)
0-255
(0) = 0% (255) = 100%
20
DIMMING CURVE MODES
0-20
STANDARD
21-40
STAGE
41-60
TV
61-80
ARCHITECTURAL
81-100
THEATRE
101-255
Default to Unit Setting
DYNAMIC DIM TO WARM CONTROL RANGE –
ADDED WITH V1.1.0
This feature provides dynamic color temperature control by allowing a specific CTH (Color
Temperature High) and CTL (Color Temp Low) to be set via the fixture’s system menu or via DMX
control. This feature provides smooth DIM to WARM dimming and superior color rendering
consistency (CRI), ensuring colors look as intended even while dimming.
DMX 20 CHANNEL MODE -
ADDED WITH V1.1.0
Channels 1-12 (LED pixels 1-12) are used to set the individual LED pixel output levels. Note channel
14 (Shutter/Strobe), 15 (Master Dimmer) and/or 16 (Dimmer FINE), must be used in order for
channels 1-12 to function. Channel 17 (CTL Control Temp Low) and Channel 18 (CTH Control Temp
High) are used to set the specific dynamic Color Temperature levels. Channel 19 is used to set the
maximum output limit of channels 1-12, 14, 15 and/or 16, without affecting the Color Temperature
values set in channels 17 and/or 18.