74
GSM signal
Flashing pattern
Indicates
Not illuminated
GSM radio off
Illuminated
Waiting for GSM module to start
Lights up 5 times*
Attempting to initiate GSM module
Lights up 4 times*
GSM module requested PIN for SIM card.
Lights up 3 times*
Module active. Waiting for GPRS network.
Lights up 2 times*
GPRS network ok. Establishing IP connection.
Lights up once*
Server connection interrupted. Initiating again.
Normal flashes
1–5 flashes.
EN
Troubleshooting
Service may be interrupted if frequency disruptions occur in the form of transients in the network.
Operational disruptions
If disruptions occur, always start by checking the signal quality and that the device is in contact with the
server.
•
If signal quality is poor, move the box so that a better signal is established.
•
If server contact is not established, reboot the device.
•
If server contact cannot be established, contact El-Björn.
Disconnection
Disconnect the power supply to the device before starting to dismantle it. Remove the battery before
storing the product for prolonged periods (if the storage period is longer than 6 months, the battery
must be trickle charged).
Servicing
Clean the main unit and the sensors between use.
Maintenance
Calibrate the sensors and make sure the connection cables are in good condition (in working order).
Troubleshooting checklist
1.
Check the power supply to the main unit.
2.
Check the power supply from the UPS.
3.
Check the LED indicators on the ezeio™.
4.
Check the sensor addressing.
5.
Check the antenna connection.
Transportation/storage
Always handle the box and sensors with care. Store the sensors indoors in a dry place.