Pellet burner GP xx sc 15
6. INITIATION TO OPERATION OF THE PELLET BURNER „GP XX SC”.
The automated modulating pellet burner from series „GP xx sc” has to be initiated
to operation only by a specialized company, authorized for such activities.
6.1.
MAIN REQUIREMENTS ABOUT THE USED FUEL TYPES.
During initiation to operation of a pellet burner from series „GP xx sc” the following main
requirements about the used fuel types must be observed:
To achieve complete fuel burning it is necessary to use only dry fuels. It is
recommended to store the fuel in dry and ventilated premises;
It is forbidden to store the fuel next to the appliance to which the burner is mounted or
at distance less than 400 mm from it;
The optimal recommended distance between the appliance (to which the pellet
burner is mounted) and the fuel is at least 1000 mm. It is preferable to store the fuel in
a neighbor room;
When installing the pellet burner from series „GP xx sc” to the desired appliance and
when storing the fuel, all fire safety requirements must be observed. It is
recommended to position a fire-extinguisher at an easy access and safe place near
the boiler.
6.2.
INITIATION TO OPERATION OF A PELLET BURNER „GP XX SC”.
When initiating to operation a pellet burner from series „GP xx sc”, the following main
requirements must be observed:
Maintenance and attendance of the burner must be performed in accordance to the
manual for maintenance and operation;
The operation mode of the system: a pellet burner from series „GP xx sc” and a heat
energy consumer, must provide minimum under-pressure (pressure lower than the
atmosphere’s) in the appliance’s combustion chamber, within range 5 – 20Pa;
Non-compliance with the above requirement might lead to emergency modes or
to ineffective operation of the burner. The value of the under-pressure in the heat
energy consuming appliance’s combustion chamber depends on the chimney
draught and on other modules (for example a flue gas extraction fan). Operation
modes, non-complying with this requirement might be ascertained through the
temperature value indicated by the reversible temperature sticker.
Any interference to the operation of the appliance that might lead to risks for the
health of the servicing/attending personal or to other indirectly linked people is strictly
forbidden;
During operation the burner has to be periodically checked by the user/attending
staff;
The user must not perform any repairs over the system’s modules. If a failure or a
problem occurs during operation then the users must ask for technical assistance by
a servicing company;
It is forbidden to increase the burner’s heating output above the nominal output;
The ash residues from the burning process must be gathered in proper fire-proof
container and after cooling to ambient temperature it has to be dumped to proper for
the purpose places.