16. STORAGE
If the compressor will not be used for a prolonged time period, drain any condensate from the air tank. Then
turn on the compressor for 10 minutes, keeping the drain valve open (1) (Fig.11, Fig.12). Switch off the
compressor by switch (3) at pressure switch (2) (Fig.10), close the drain valve and disconnect the appliance
from the mains.
17. DISPOSING OF THE APPLIANCE
• Disconnect the appliance from the mains.
• Release air pressure in the pressure tank by opening the drain valve (1) (Fig.11, Fig.12).
• The components of the product are non-toxic.
• Dispose of the appliance following all environmental regulations.
18. REPAIR SERVICE
Guaranteed and post-guarantee repairs must be done by the manufacturer, its authorized representative, or
service personnel approved by the supplier.
The manufacturer reserves the right to make changes to the appliance without notice. Any changes made
will not affect the functional properties of the appliance.
19. SOLVING PROBLEMS
Caution! Before proceeding, depressurize the air tank to zero and disconnect the
appliance from the mains.
Troubleshooting can be performed only by qualified personnel.
FAILURE POSSIBLE
CAUSE
REMEDY
No voltage in pressure switch
Check voltage in socket
Check fuse – replace faulty one
Loosen terminal – tighten it
Check power cord – replace faulty one
Compressor does not
start
Disconnected winding of motor,
damaged thermal protection
Faulty capacitor
Seizure of piston or another rotary part
Pressure switch does not switch on
Replace motor or re-wind it
Replace capacitor
Replace damaged parts
Check the function of pressure switch
Compressor often
switches on
Air leak in pneumatic distribution
system
Leaking check valve
Greater volume of condensed liquid in
pressure vessel
Check pneumatic distribution system –
seal loose joint
Clean valve, replace seals, replace valve
Drain condensed liquid
Prolonged running
of compressor
Air leak in pneumatic distribution
system
Worn piston ring
Contaminated input filter
Dirty filter in the dryer
Defective solenoid valve
Check pneumatic distribution system –
seal loose joint
Replace worn piston ring
Replace contaminated filter with the new
one
Change outlet filter and inspect dessicant
Repair or change the valve
Compressor is noisy
(knocking, metal
noises)
Damaged bearing of piston, piston
rod, motor bearing
Loose or cracked spring
Replace damaged bearing
Replace damaged spring
Dryer doesn´t dry
(condensed water in
the tank)
Devaluated or very polluted dessicant Change the dessicant and filters
Содержание DK50 Plus Mobile
Страница 1: ......
Страница 2: ......
Страница 3: ...DK50 DK50 PLUS 10 2009 1 NP DK50_5 OBSAH 2 CONTENTS 18 34 INHALT 51 SOMMAIRE 67 SPIS TRE CI 83 Ed 4...
Страница 37: ...DK50 DK50 PLUS 10 2009 35 NP DK50_5 1 CE CE 93 42 EEC 2 2 1 2 2...
Страница 38: ...DK50 DK50 PLUS NP DK50_5 36 10 2009 2 3 3 CE...
Страница 44: ...DK50 DK50 PLUS NP DK50_5 42 10 2009 3 MONZUN M1a 4 MONZUN M1 10 5...
Страница 45: ...DK50 DK50 PLUS 10 2009 43 NP DK50_5 6 DK50 PLUS S 7 KJF1...
Страница 46: ...DK50 DK50 PLUS NP DK50_5 44 10 2009 8 X Y 9 5 C 40 C 70 6 10 10 1...
Страница 52: ...DK50 DK50 PLUS NP DK50_5 50 10 2009 16 10 1 11 12 3 2 10 17 1 11 12 18 19...
Страница 104: ......