12. FIRST OPERATION
(Fig.10)
•
Make sure that all stabilizers used during transport were removed.
•
Check that all pressurized air line connections are secure.
•
Connect to the mains.
•
Start compressor at pressure switch (2) by turning switch (3) to position “I.“
•
For kompressor DK50 PLUS S turn the switch (29) (Fig.6) at the front part of the soundproof box to the
position “I“ – green light indicates that the appliance is on.
Compressor
- At first operation the air tank is pressurized until it reaches a preset level when the
compressor automatically switches off. As the air is used, the compressor works in automatic mode,
switched on or off by the pressure switch.
Compressor with dryer
- In addition, the adsorption dryer takes out the humidity from the previous
compressed air during operation and it blows out the entrapped condensate via condensate outlet, which
can be heard as a short hiss when compressor is stopped.
Compressor with condensation and filtration unit
- Model KJF-1 filters and dehumidifies the air and
automatically releases condensed liquid through the filter´s discharge valve.
The compressor is not equipped with an emergency power supply.
OPERATION
In case of emergency, disconnect the compressor from the mains (pull out the mains
plug).
The compressor has hot surfaces.
Burns or fire may result if contact is made.
During prolonged operation of the compressor, the temperature in the box may increase to
over 40°C. At this point the cooling fan automatically switches on. After cooling the
space to under 32°C, the ventilator switches off.
Automatic start: when pressure in the tank drops to the pressure switch’s lower limit level,
the compressor automatically switches on.
The compressor automatically switches off
after reaching the pressure switch’s upper limit level.
13. SWITCHING THE COMPRESSOR ON
(Fig.10)
Switch on the compressor at the pressure switch (2) by turning the knob (3)
to position “I.” (for DK50 PLUS S switch on also switch (29) Fig.6, on the
front part of the compressor box), The compressor sends pressurized air to
the air tank. As the compressed air is used, the pressure in the air nozzle
drops to a preset level, the compressor switches on and the air nozzle files
with compressed air. After reaching the cutoff pressure the compressor
turns off automatically and the cycle is repeated. Check the value of
switching-on and switching-off pressure on pressure gauge. The values
may be within a tolerance of
±
10%. Air pressure in air chamber must not
exceed maximal permitted operation pressure.
Never tamper with the pressure switch (2). Adjustments are not allowed. The pressure
switch (2) has been set by the manufacturer and further setting of switching on and off
pressure may be carried out only by a qualified expert trained by the manufacturer.
Fig.10
3
5
2
1
4
Содержание DK50 Plus Mobile
Страница 1: ......
Страница 2: ......
Страница 3: ...DK50 DK50 PLUS 10 2009 1 NP DK50_5 OBSAH 2 CONTENTS 18 34 INHALT 51 SOMMAIRE 67 SPIS TRE CI 83 Ed 4...
Страница 37: ...DK50 DK50 PLUS 10 2009 35 NP DK50_5 1 CE CE 93 42 EEC 2 2 1 2 2...
Страница 38: ...DK50 DK50 PLUS NP DK50_5 36 10 2009 2 3 3 CE...
Страница 44: ...DK50 DK50 PLUS NP DK50_5 42 10 2009 3 MONZUN M1a 4 MONZUN M1 10 5...
Страница 45: ...DK50 DK50 PLUS 10 2009 43 NP DK50_5 6 DK50 PLUS S 7 KJF1...
Страница 46: ...DK50 DK50 PLUS NP DK50_5 44 10 2009 8 X Y 9 5 C 40 C 70 6 10 10 1...
Страница 52: ...DK50 DK50 PLUS NP DK50_5 50 10 2009 16 10 1 11 12 3 2 10 17 1 11 12 18 19...
Страница 104: ......