INSTALLATION
NP-DK50-9x4VRTM-AD-EN-5_04-2022
26
04/2022
AD dryer compressed air inlet
•
Connect the compressed air outlet from
the compressor (Fig. 15) to the dryer inlet
(1).
•
A G 1” connection is installed.
Fig. 15: Compressed air inlet
Burn or fire hazard! Caution! Hot
surface!
When installing the connecting
hoses at the inlet to the air dryer,
ensure that the temperature is
not hazardous if it was to come
into contact with an operator or
other material.
AD dryer compressed air outlet
•
Connect the air outlet from the dryer (1) to
the inlet on the air tank.
•
A G 1” connection is installed.
Fig. 16: Compressed air outlet
Condensate outlet from dryer
•
Connect a hose to the outlet (1)
from the automatic condensate
drain (2) to drain piping or to the
provided collection vessel.
A noise silencer is recommended when
connecting directly to drain piping.
Содержание 447000001-066
Страница 1: ...DK50 9x4VRT M User manual...
Страница 2: ......
Страница 13: ...PRODUCT DESCRIPTION 04 2022 13 NP DK50 9x4VRTM AD EN 5_04 2022 Fig 2 Electrical box switchboard...
Страница 15: ...TECHNICAL DATA 04 2022 15 NP DK50 9x4VRTM AD EN 5_04 2022 Dependence of compressor output on working pressure...
Страница 20: ...INSTALLATION NP DK50 9x4VRTM AD EN 5_04 2022 20 04 2022 Fig 5 Levelling the compressor Fig 6 Frame installation...
Страница 35: ...INSTALLATION 04 2022 35 NP DK50 9x4VRTM AD EN 5_04 2022 15 PNEUMATIC DIAGRAMS DK50 9x4VRT M DK50 9x4VRTS M...
Страница 66: ...ANNEX NP DK50 9x4VRTM AD EN 5_04 2022 66 04 2022 ANNEX 22 MAPPING PARAMETERS...
Страница 67: ...ANNEX 04 2022 67 NP DK50 9x4VRTM AD EN 5_04 2022...
Страница 69: ......
Страница 70: ......
Страница 71: ......