It is important that the following clearances are maintained from the appliance to combustible materials and are dependant on the desired
mounting location as defined below.
This appliance is designed to be wall mounted only. Do not stand it on the floor.
The minimum distance from the top of the appliance to a ceiling is 500mm.
The minimum distance from the bottom of the appliance to the floor is 100mm.
The minimum distance to the sides of the appliance is 100mm.
The minimum distance to the front of the appliance is 500mm.
4.0 SITE REQUIREMENTS
5.0 CLEARANCES TO COMBUSTIBLE MATERIALS
©
2016 Focal Point Fires plc.
3
3.0 ELECTRICAL INSTALLATION REQUIREMENTS
• DO NOT run the mains cable under carpets, rugs etc.
• DO NOT cover or obstruct the heater in any way. Overheating will result if it is acci-
dentally covered.
• Never immerse the product in water or any other liquids.
• DO NOT use the appliance outdoors.
• Before cleaning the appliance, ensure it is unplugged from the power and that it is com-
pletely cool.
• DO NOT clean the appliance with abrasive chemicals.
• Never use accessories that are not recommended or supplied by the manufacturer. It
could cause danger to the user or damage to the appliance.
• DO NOT insert or allow foreign objects to enter the inlet or outlet vents as this may
result in electric shock, fire or damage to the appliance.
• DO NOT install the fire using an extension cord.
• Unplug from the mains supply if the appliance is not to be used for long periods.
The appliance is designed to be wall mounted via the wall mounting plate and fixings provided. The wall should be relatively flat and not inter-
fere with any of the ventilation slots in the appliance casing.
The wall must be structurally sound and of a material capable of withstanding moderate heat. Finished plaster, conventional wallpaper, dry-lined
plaster board are examples of suitable materials. Materials such as “flock” blown vinyl”, embossed paper and cloth wall coverings which are sen-
sitive to even small amounts of heat should be avoided, as some discolouration may occur. It should be noted that the appliance creates warm
convected air currents. These currents move heat from the room surroundings to, and up the wall surfaces adjacent to the heater.
Installing the heater next to these types of wall coverings or operating the heater where impurities in the air, (such as tobacco smoke) exist,
may slightly discolour wall finishing.
If the appliance is to be mounted on a dry lined or timber framed construction then the integrity and ability of the wall to carry the weight of
the appliance must be confirmed. It is important in these circumstances that any vapour barrier and/or structural members of the house frame
are not damaged. If you are unsure of the ability of the wall to carry the weight and/or which type of wall fixing to use, you should take pro-
fessional advice and obtain the correct fixings. Alternatively, find a more suitable wall location.
DO NOT
-
mount on a ceiling or floor.
-
recess any part of the appliance into the wall.
-
site any electrical equipment e.g. plasma screen TV sets etc,
on the wall above the appliance.
-
site in a position where curtains or drapes could cover the appliance.
-
site in a position where other soft materials could cover e.g. below a coat rack.
-
site behind an opening door where mechanical impact/damage could occur.
-
site where the supply cable would become a trip hazard.
-
sit, stand or forcefully pull on the appliance.
-
obstruct, cover or force items into the openings.
-
use the heater to dry clothes.
-
site/use in an outdoor location(s).
-
run the supply cable under carpets.
2.0 APPLIANCE DATA
Weight (kg):
17.0 kg
Supply Cord:
2 metres
Dimensions (mm):
H 466 x W 757 x D 100
Fuse:
13Amp
Supply Voltage and rating power: 220-240V a.c. 50/60Hz, 1716 - 2016
Location:
Indoor Use
Heating Elements:
2 x 900/1000Watts (1.8 - 2.0kW)
LCD Display:
16 Watts
DO NOT RECESS ANY PART OF THE APPLIANCE.
The appliance is supplied with a pre-wired three pin plug (13 Amp fuse rated), and 2 metre cable. A standard switched outlet/wall socket, (includ-
ing earth provision), must therefore be located within this distance, and be easily accessible in order to isolate the supply for maintenance and
cleaning. This socket must not be mounted behind or above the appliance.
IMPORTANT: THIS APPLIANCE MUST BE EARTHED.