6
©
2016 Focal Point Fires plc.
ALWAYS DISCONNECT THE APPLIANCE AT THE SUPPLY OUTLET SOCKET BEFORE UNDERTAKING ANY CLEANING.
Except for periodic cleaning of dust, there are no specific requirements for care, other than regular cleaning of the general appliance. A wipe
with a dry cloth is normally sufficient. DO NOT use abrasive cleaners as they can damage the finish. Make sure the heater outlet grille (locat-
ed on the top panel), and the air inlet mesh grilles (located on the sides and base panel) are kept clear of dust, pet hair and other airborne
household matter. These should be vacuum cleaned periodically using a brush attachment.
GLASS FACIA PANEL - This should only be cleaned using a suitable glass cleaner. Test on a small area first.
11.0 CLEANING AND MAINTENANCE
12.0 SERVICING
There are no internal user serviceable parts.
Check regularly for security of wall fixings as appropriate. Also check security of supply cable and connections. If the supply cable
becomes damaged, it must be replaced by a service agent or competent person, such as a qualified electrician.
This appliance is supplied with a 3 pin plug fitted with a 13 Amp fuse. Should the fuse require replacing, it must be replaced
with a fuse rated at 13 Amp. In the event of the mains plug being removed/ replaced for any reason, please note : IMPOR-
TANT: The wires in the mains lead are coloured in accordance with the following code:
Blue - Neutral
Brown - Live
Green/ Yellow - Earth
As the colours of the wires in the mains lead of this appliance may not correspond
with the colour markings identifying the terminals in your plug, proceed as follows.
The blue wire must be connected to the terminal marked with an N or coloured
black. The brown wire must be connected to the terminal marked with an L or
coloured red. The green/yellow wire must be connected to the earth terminal which
is marked with an E or with the earth symbol. WARNING: Never connect live or
neutral wires to the earth terminal of the plug.
NOTE: If a moulded plug is fitted and has to be removed take great care in disposing
of the plug and severed cable, it must be destroyed to prevent engaging into a sock-
et.
Refer to Section 2.0, Appliance Data for fuse specification. Excluding fuses, use only
genuine manufacturers spare parts available from your supplier.
10.0 SAFETY CUT-OUT SYSTEM
NOTE: The LCD display panel will remain operational if the cut-out is activated, only the fan heater elements are prevented
from operating.
This product has one non-self-resetting overheat protection device (thermal cut-out) which will activate if the air inlets or out-
lets are obstructed. For safety reasons the fire will NOT switch on again automatically, the following procedure must be carried
out before the fire can be operated.
NOTE: The visual effect will remain operational if the cutout is activated, only the fan heater is prevented from working.
Switch OFF the appliance at the wall socket or outlet. Leave the fire OFF for a period of no less than 10 minutes, ensuring all
obstructions are removed. Switch the appliance ON at the wall. Ensure the appliance is turned ON at the control switches. If
the fire fails to operate correctly, repeat the above procedure. If an attempt to switch on the appliance is made before the safe-
ty cutout has reset, the appliance may cutout for a further period of time. If the sequence has been followed correctly and the
appliance still fails to function, check the fuse in the wall outlet. If this is not the cause, call an electrician or maintenance engineer.
GB IE
Figure 15