background image

6

©

2016 Focal Point Fires plc.

ALWAYS DISCONNECT THE APPLIANCE AT THE SUPPLY OUTLET SOCKET BEFORE UNDERTAKING ANY CLEANING.

Except for periodic cleaning of dust, there are no specific requirements for care, other than regular cleaning of the general appliance. A wipe

with a dry cloth is normally sufficient.  DO NOT use abrasive cleaners as they can damage the finish. Make sure the heater outlet grille (locat-

ed on the top panel), and the air inlet mesh grilles (located on the sides and base panel) are kept clear of dust, pet hair and other airborne

household matter. These should be vacuum cleaned periodically using a brush attachment.

GLASS FACIA PANEL - This should only be cleaned using a suitable glass cleaner. Test on a small area first.

11.0 CLEANING AND MAINTENANCE

12.0 SERVICING

There are no internal user serviceable parts.

Check regularly for security of wall fixings as appropriate. Also check security of supply cable and connections. If the supply cable

becomes damaged, it must be replaced by a service agent or competent person, such as a qualified electrician.

This appliance is supplied with a 3 pin plug fitted with a 13 Amp fuse. Should the fuse require replacing, it must be replaced

with a fuse rated at 13 Amp. In the event of the mains plug being removed/ replaced for any reason, please note : IMPOR-

TANT: The wires in the mains lead are coloured in accordance with the following code:

Blue - Neutral

Brown - Live

Green/ Yellow - Earth

As the colours of the wires in the mains lead of this appliance may not correspond

with the colour markings identifying the terminals in your plug, proceed as follows.

The blue wire must be connected to the terminal marked with an N or coloured

black. The brown wire must be connected to the terminal marked with an L or

coloured red. The green/yellow wire must be connected to the earth terminal which

is marked with an E or with the earth symbol. WARNING: Never connect live or

neutral wires to the earth terminal of the plug.

NOTE: If a moulded plug is fitted and has to be removed take great care in disposing

of the plug and severed cable, it must be destroyed to prevent engaging into a sock-

et.

Refer to Section 2.0, Appliance Data for fuse specification. Excluding fuses, use only

genuine manufacturers spare parts available from your supplier.

10.0 SAFETY CUT-OUT SYSTEM

NOTE:  The LCD display panel will remain operational if the cut-out is activated, only the fan heater elements are prevented
from operating. 

This product has one non-self-resetting overheat protection device (thermal cut-out) which will activate if the air inlets or out-

lets are obstructed. For safety reasons the fire will NOT switch on again automatically, the following procedure must be carried

out before the fire can be operated.

NOTE: The visual effect will remain operational if the cutout is activated, only the fan heater is prevented from working.

Switch OFF the appliance at the wall socket or outlet. Leave the fire OFF for a period of no less than 10 minutes, ensuring all

obstructions are removed. Switch the appliance ON at the wall. Ensure the appliance is turned ON at the control switches. If

the fire fails to operate correctly, repeat the above procedure. If an attempt to switch on the appliance is made before the safe-

ty cutout has reset, the appliance may cutout for a further period of time. If the sequence has been followed correctly and the

appliance still fails to function, check the fuse in the wall outlet. If this is not the cause, call an electrician or maintenance engineer.

GB IE

Figure 15

Содержание SE2015

Страница 1: ...y Focal Point Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc 1 Revision F 02 16 2016 Focal Point Fires plc GB IE WAL...

Страница 2: ...rning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision...

Страница 3: ...ld be noted that the appliance creates warm convected air currents These currents move heat from the room surroundings to and up the wall surfaces adjacent to the heater Installing the heater next to...

Страница 4: ...den members of the wall using two of the fixing screws provided If this is not achievable then the wall should be strengthened using appropriate building materials If there is no alternative than to r...

Страница 5: ...scene Fig 8 Gas fire medium Fig 9 Gas fire high Fig 10 Gas fire Blue Flame Fig 5 Log fire Fig 6 Twig fire Fig 7 Coal fire Scene select buttons Volume and mute buttons Figure 14 LCD on off control Con...

Страница 6: ...ith an N or coloured black The brown wire must be connected to the terminal marked with an L or coloured red The green yellow wire must be connected to the earth terminal which is marked with an E or...

Страница 7: ...hird party who undertakes any work carried on the product or fits parts unless we have approved such work in advance of it being carried out The guarantee period will not be extended even if we repair...

Отзывы: