8.0 FIXING THE APPLIANCE 

DO NOT connect the appliance to the supply at this stage. Remove the single thumbscrew from

the middle of the base panel of the appliance, then remove the wall mounting plate from the appliance.

After having selected the final mounting position of the appliance, taking into account the requirements as spec-

ified in sections 3.0, 4.0 and 5.0 of these instructions, the integrity of the wall, and the feasibility of the proposed

supply cord routing, the wall mounting plate may be secured to the wall.  To ensure safety, be sure to design the

installation so that the strength of both the wall and any wall fixings used are sufficient. 

Focal Point Fires plc. assumes absolutely no responsibility for injuries and damages that may occur due to

improper installation or handling. The appliance should not be installed until all wet plastering and/or dry

wall sanding and wall painting has been completed.  Do not block the ventilation holes of the appliance.

The wall onto which the appliance is installed must be flat. Install only on a vertical surface. Avoid sloped 

surfaces. Installation onto anything other than a vertical wall may result in fire, damage or injury.

If the appliance is to be mounted on the inner leaf of a conventional cavity brick wall, or a solid

wall, then the wall plugs and fixing screws provided may be used. Depending on the condition of

the wall it may be necessary to use additional fixings. In this

situation, any additional fixings and wall plugs should be of

the same size and type as the ones provided. Using a spirit

level  to  check  correct  horizontal  alignment,  hold  the  wall

mounting plate in the desired position and using a pencil,

mark  out  the  position  of  the  fixing  holes  on  the  wall.

Remove  the  mounting  plate  from  the  wall  and  drill  four

holes using only a 8.0mm masonry bit to a depth of 43mm.

Insert the wall plugs provided ensuring they are flush to the wall. Using the screws provided, fix

the mounting plate to the wall.

If  the  appli-

ance is to be

mounted  on

a  dry  lined

wall  or  a

t i m b e r

framed  con-

s t r u c t i o n

wall then efforts should be made to fix in at least two posi-

tions vertically, into one of the wooden studs, or supporting

wooden members of the wall using two of the fixing screws

provided.  If  this  is  not  achievable  then  the  wall  should  be

strengthened using appropriate building materials. 

If there is no alternative than to rely on some plasterboard

fixings  then  special  cavity  screw  fixings  or  hollow  wall

anchors will be required which are not supplied with this

product. These should be constructed from metal and not

plastic and of the design indicated in figure 3. 

With the wall plate secured in position the heater unit can

be hung onto the wall plate. Ensure the two hooks at the top

of  the  wall

plate  fully

engage  the

k e y h o l e

shaped  holes

in the brack-

ets  at  the

top  of  the

heater back panel as shown in figure 4.

Finally re-fit the thumbscrew to the base panel of the heater via the tab at the bottom of the wall

plate (see figure 2). This fixes the heater to the wall plate and will prevent the heater from falling off the wall in the event it is accidentally

knocked, for example.

©

2016 Focal Point Fires plc.

Plasterboard alone is not considered

to be a structural material.

It  is  not  recommended  to  rely  on

plasterboard  fixings  alone  to  sup-

port the weight of the appliance.

WARNING

The  wall  where  the  appliance  is  to

be installed must be capable of long-

term support of the total load of the

appliance.  Measures  should  also  be

taken  to  ensure  sufficient  strength

to  withstand  the  force  of  earth-

quakes, vibration and other external

forces.

WARNING

Ensure the frame is fitted correctly

and the remote control infrared sen-

sor can be seen through the hole in

the middle of the lower glass panel. If

not, appliance will not receive signals

from the handset.

IMPORTANT

Figure 4

Figure 3

Figure 2

QUANTITY

DESCRIPTION

1

Heater unit including LCD display

1

Decorative glass facia

1

Remote control handset

1

Wall mounting plate

1

Mains supply cord

1

Instruction Booklet

4

37mm long round head screws

Wall plugs

7.0 COMPONENT CHECKLIST

Caution: This appliance is heavy. Always seek assistance whilst unpacking and/or during installation. Read all  the instructions

before continuing to unpack or install this appliance. Carefully remove the appliance from its packaging and lay on the floor with it’s back sur-

face downward.  Check that the remaining packaging contents correlate with the component checklist below. Please dispose of all packaging

with care at your local recycling centre.

6.0 UNPACKING THE APPLIANCE

GB IE

Содержание SE2015

Страница 1: ...y Focal Point Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc 1 Revision F 02 16 2016 Focal Point Fires plc GB IE WAL...

Страница 2: ...rning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision...

Страница 3: ...ld be noted that the appliance creates warm convected air currents These currents move heat from the room surroundings to and up the wall surfaces adjacent to the heater Installing the heater next to...

Страница 4: ...den members of the wall using two of the fixing screws provided If this is not achievable then the wall should be strengthened using appropriate building materials If there is no alternative than to r...

Страница 5: ...scene Fig 8 Gas fire medium Fig 9 Gas fire high Fig 10 Gas fire Blue Flame Fig 5 Log fire Fig 6 Twig fire Fig 7 Coal fire Scene select buttons Volume and mute buttons Figure 14 LCD on off control Con...

Страница 6: ...ith an N or coloured black The brown wire must be connected to the terminal marked with an L or coloured red The green yellow wire must be connected to the earth terminal which is marked with an E or...

Страница 7: ...hird party who undertakes any work carried on the product or fits parts unless we have approved such work in advance of it being carried out The guarantee period will not be extended even if we repair...