Disposal of the module 

 

AIM2505A Technical Manual V2.03

 

 

50

 

 

11. Disposal of the module 

 

 
In order to reduce the environmental load over the product’s entire lifecycle,  
EKE-

Electronics’ products are designed to be as safe as possible to manufacture, 

use, and dispose of. 

 

Parts which can be recycled should always be taken to the appropriate processing 
centres, after hazardous waste has been removed. All parts and components 
containing hazardous materials must be disposed of in accordance with waste 
legislation and instructions issued by the environmental authorities. The risks 
involved and the necessary precautions must be taken into account when handling 
waste products. Therefore, please execute proper processing of disposal in 
accordance with local law. 
 

Table 11.1 

Disposal of the AIM module, X = action, (X) = action in cases where 
processing is available 

 

Part 

Main materials 
of disposal 

Recyclable 
materials 

Waste disposal 
sites 

Hazardous waste 
(separate 
collection) 

Frame and 
covers 

Metal 

Plastic 

 

Rubber 

 

Aluminium 

Stainless steel 

PUR, PU 

Other plastics 

 

 

 

 

 

 

 

Component 
boards 

 

 

Lead 

(X) 

 

 

 

 

 

Packing 

 

Cardboard 

PE 

 

 

 

Содержание EKE-Trainnet AIM2505A

Страница 1: ...EKE Trainnet AIM2505A Analog Input Module Technical Manual...

Страница 2: ...support eke com The most recent information on EKE Electronics products and services is available at www eke com Under copyright law no part of this document may be copied reproduced or transferred e...

Страница 3: ...Installing the I O cable on the module 15 Checking that the module works correctly 15 3 3 1 Memory Self Test 15 3 3 2 Status Indicator LEDs 16 3 3 3 Using the Portable System Tester PST software 16 Po...

Страница 4: ...er specifications 40 8 2 1 X1 IO Connector 40 8 2 2 X2 VME CONNECTOR 41 8 2 3 X4 DLOAD CONNECTOR 42 Electrical specifications 43 Reliability specifications 43 Non metallic parts 44 Compliance with sta...

Страница 5: ...IM Binary tree Chapter 6 Troubleshooting Chapter 7 Firmware loading Chapter 8 Technical specifications Chapter 9 Cable recommendations Chapter 10 Diagrams This manual does not include information on o...

Страница 6: ...ing symbols The warning symbols appear in the beginning of the appropriate chapter The following symbols are used Figure 1 1 Electric shock warning symbol Figure 1 2 ESD warning symbol Figure 1 3 Gene...

Страница 7: ...the module are intended to protect module only from external surges and transients They do not provide protection against incorrect wiring or connection Correct handling of the module Electrostatic d...

Страница 8: ...verview of the AIM module This chapter lists selected specifications of the AIM module and highlights some of its features The following topics are covered in this chapter Selected specifications Modu...

Страница 9: ...Width 4 TE Height 3 U Weight 160g Required free space in front of the module 75 mm Operating voltage 5 VDC 4 75 5 25 VDC Operating temperature 40 70 C Analog inputs Number of voltage inputs 10 Number...

Страница 10: ...fication field is for the entire module The circuit board may have a different modification level indicated by numbers which are printed on the board s modification field This is found on the back sid...

Страница 11: ...loop Group 2 has two voltage and current inputs Groups 3 and 4 are identical and they have four voltage and current inputs and one voltage output pin for external sensors or current loops Figure 2 2...

Страница 12: ...surement resolution is 13 bits and the step size in the input register is 10 A 2 4 2 Frequency inputs The frequency inputs can be used to measure frequency pulse width ratio and pulse count The input...

Страница 13: ...installation of the rack Never remove the AIM module from a rack Always turn OFF the rack power first BEFORE removing the rack Electrostatic discharge can damage electronic circuits Always handle the...

Страница 14: ...ent Installation procedure The following sections include instructions for installing the AIM module into a rack 3 2 1 Installing the AIM module into the rack 1 Check that the coding pins are installe...

Страница 15: ...project specifications 2 Check that the installed I O cable fulfils the cable requirements described in the Cable Recommendations chapter 3 Connect the cable to the module I O interface without using...

Страница 16: ...1 System error SE System OK System error occurred module in reset Self tests failed Green H2 Status ST If SE red led is also off no power System OK System OK communication with host CPU Green H3 FPGAD...

Страница 17: ...does not fit into the rack The connector pins of the module are damaged Replace the module with a spare one Connector pins are OK but the module does not fit into the rack The back plane of the rack i...

Страница 18: ...are referred to as CPU The following figure shows the principal connection between the AIM module and the CPU Figure 4 1 AIM CPU connection On the CPU side an I O bus master called CIAO manages all c...

Страница 19: ...about racks and IO bus slot addresses I O Connector pins The following table show each channel and its related pins on connector X1 Table 4 1 AIM IO Connector pinout Connector X1 Pin Signal Pin Signal...

Страница 20: ...e phase shifted in respect to each other Another pair can be made from FREQ3 and FREQ4 This enables applications such as measurement of train travel distance to be aware of travel direction which then...

Страница 21: ...ps 2 3 and 4 AIM module has two voltage and two current channels group 2 It has also two identical groups group 3 and 4 with four voltage and four current channels Figure 4 4 Current and voltage input...

Страница 22: ...ll channels of a group are internally connected together and therefore no voltage difference between GROUPxVSSI pins are allowed Each channel has its own third order low pass filter which removes unwa...

Страница 23: ...re The AIM module has its own thermometer that measures the temperature of the module continually with 3 C Celsius accuracy The thermometer is inbuilt in the control microprocessor Because the process...

Страница 24: ...ng the registers must know what data each register represents and how to interpret it Information how to use Binary tree with ISaGRAF application is available by request from EKE Electronics Ltd This...

Страница 25: ...pped Table 5 3 Status registers Register Description Significant bits Range Function 33 Selfcheck status Always 0 Reserved for future use 34 Selfcheck status Always 0 Reserved for future use Table 5 4...

Страница 26: ...quency input 1 pulse width ratio Unsigned 16 bit integer Range 0 0 100 0 Pulse width ratio for frequency inputs Resolution is 0 1 90 Frequency input 2 pulse width ratio 91 Frequency input 3 pulse widt...

Страница 27: ...e 0000 9999 This register is 0000 if the firmware is not project specific default 204 SW version patch number 000 999 Range 000 999 Minor release number 205 Module name 0 ASCII char A I M 2 5 0 5 A 0...

Страница 28: ...22 Reserved The value in the register is always zero Register 23 Heartbeat Heartbeat bits 0 7 is the value of AIM2505A module s internal 16ms tick counter Bits 15 8 are reserved The value wraps aroun...

Страница 29: ...8 Frequency inputs frequency These give the measured frequency value with 0 25 Hz resolution for the four frequency inputs This means that the application must divide the register value by four to get...

Страница 30: ...gital input channels Registers 98 Phase direction for frequency input 1 versus input 2 The frequency inputs 1 and 2 can be paired to measure phase direction between pulses in these two inputs Base for...

Страница 31: ...t number The module firmware release project number The range is 0 9999 This register is zero if the firmware is not project specific Register 204 SW version Patch number The module firmware release p...

Страница 32: ...pful when testing the Train Management System s operation The following topics are discussed in this chapter Warnings Preparations Visual check Getting started with troubleshooting Opening the Remote...

Страница 33: ...Cabling Check that all cabling is correct according to the project specific cabling diagram Also check that the cables and wires are undamaged and attached properly Getting started with troubleshooti...

Страница 34: ...The Remote Terminal session needs to be started from the CPU console Figure 6 1 Remote terminal connection to the AIM via Coach Computer CPU To make sure that the CPU console is working press Enter f...

Страница 35: ...listing removed to save space 378 root 1980 S tcnker f var opt tms base tcn dat i 40 40 50 7 380 root 980 Suic 556 i 1 m 0 l 255 o 255 b 1 a 255 383 root 756 Sciao p dev iobus b 4 s 200000 d 5 r 100 3...

Страница 36: ...ge from 1 to 9 and a to z 06 node number AIM2505A Module name 123123 Module serial number 0 H 0103291 Additional module information 4 Select the module by typing the number or letter at the TC MENU Th...

Страница 37: ...mmands have multiple parameters which must be separatedby spaces A vertical bar between values means that only one of the listed choices can be used for a single command 6 6 2 Command help print avail...

Страница 38: ...s that the frequency input 1 sees a frequency of 1000 Hz and 1001 Hz in successive readings and the frequency input 2 sees 400 Hz and 399 Hz The pulse counter values can be seen incrementing after suc...

Страница 39: ...f the module See figure 7 1 below for the location of X4 5 Double click the firmware file to be loaded e g AIM2505A_B015_P0000_001 ufo The loading will start and a loading progress window will appear...

Страница 40: ...wing tables include the connector specifications and pin order for the AIM 8 2 1 X1 IO Connector This connector is DIN 41612 F 48 male Table 8 2 Pin order Connector X1 Pin no Signal name Signal descri...

Страница 41: ...1 ground z4 GROUP1VSSI Group 1 ground z6 GROUP1VSSI Group 1 ground z8 PE Protection Earth z10 GROUP2VSSI Group 2 ground z12 GROUP2VSSI Group 2 ground z14 PE Protection Earth z16 GROUP3VSSI Group 3 gr...

Страница 42: ...X4 DLOAD CONNECTOR Connector provides download interface to the module Connector is 16 pin dual row pin header Only the pins associated with a signal are described in the table below Table 8 4 DLOAD C...

Страница 43: ...nput range Input resolution Input accuracy Input voltage Input positive going threshold Input negative going threshold 0 16 kHz 0 25 Hz 0 1 0 36 V 8 V 7 V Table 8 6 Module electrical specifications Pa...

Страница 44: ...fire Table 8 8 Non metallic parts Material Amount Polyester 50 g Acrylics 5 1 g FR 4 UL94 V0 58 g Compliance with standards The following table specifies the compliance of the AIM module with standar...

Страница 45: ...068 2 27 Ea 50 m s2 for 30 ms Fire protection EN 45545 2 2013 The following table specifies the EMC test details of the AIM module Table 8 11 EMC test specifications Parameter In conformance with Test...

Страница 46: ...ielded twisted pair shall be used so that the outer shielding is connected to the metallized connector housing and each pairs own shield is connected to the Protection Earth PE pins next to the channe...

Страница 47: ...ing 09 06 248 3201 Housing Harting 09 06 048 0521 Code comp Harting 09 06 000 9984 Code pin Harting 09 06 001 9905 Crimp contact 0 14 0 56mm2 Harting 09 06 000 8471 Connector 0 50 1 50mm2 Harting 09 0...

Страница 48: ...10 Diagrams This appendix includes the following diagrams of the EKE Trainnet AIM module Assembly diagram Schematic diagram Figure 10 1 Assembly diagram of the AIM module component side Figure 10 2 As...

Страница 49: ...Diagrams 49 AIM2505A Technical Manual V2 03 Figure 10 3 Top level Schematic diagram of the AIM module...

Страница 50: ...be disposed of in accordance with waste legislation and instructions issued by the environmental authorities The risks involved and the necessary precautions must be taken into account when handling w...

Отзывы: