Technical Specifications
AIM2505A Technical Manual V2.03
44
Non-metallic parts
The following table specifies the non-metallic parts used in the AIM module.
The values displayed in this table are aimed at helping to estimate the
environmental impact potentially caused by the AIM module in case
of fire.
Table 8.8
Non-metallic parts
Material
Amount
Polyester
50 g
Acrylics
5.1 g
FR 4, UL94-V0
58 g
Compliance with standards
The following table specifies the compliance of the AIM module with standardized
tests.
Table 8.9
Characteristic tests
Test
Reference
Test conditions
Visual inspection
EN 50155
Performance
EN 50155
Ambient temperature
(25 °C ± 10°C)
Insulation
EN 50155,
500 VDC
Isolation (voltage withstand) EN 50155
1 kVAC at 50 Hz, 1 min.
Conformal coating
Yes, acrylics, UL approved,
MIL-I-46058C