increase the system’s security. For this purpose, open
the page
System / Network
.
1.
Deactivate the checkbox
Discovery
.
2.
Click
Save
to apply your changes.
i
Information
Querx
may no longer be accessible by some
applications if the Discovery Service is deactivated.
8.4 Configuring the Data Logger
egnite Querx features an integrated data logger that
tracks the following data in configurable time intervals:
Peak, minimum and average temperature values
TH and THP models:
Peak, minimum and average
humidity values
THP models:
Peak, minimum and average pressure
values
Querx THP can save up to 36,864 entries. Querx TH and
PT have a capacity of 73,728 entries. The WLAN models
can record 4 million entries. This means that Querx THP
can store data for 25 days when logging one entry per
minute. Querx TH and PT can track data for 51 days and
the WLAN models can record data for 7.5 years, when
using the same settings.
Data compression can be activated, in order to increase
the timespan that can be logged. If compression is
activated, entries are only saved if any change has
occurred since the last entry.
The memory is designed as a ring memory. If the
memory’s maximum capacity is reached, the oldest
entries will be overwritten.