Please refer to below parameter setting list for an overall description and note that the available
parameters may vary depending on different models. Please always see the original product manual for
detailed setting instructions.
Parameter setting list:
Item
Description
Output setting
Output source
priority
To configure load power source priority.
AC input range Input voltage range selection
Output voltage To set output voltage.
Output
frequency
To set output frequency.
Battery
parameter
setting
Battery Type
Select connected battery type
Battery Cut-off
Voltage
Set battery cut-off voltage
Bulk Charging
Voltage
Set battery bulk charging voltage
Battery Float
Voltage
Set battery floating charging voltage
Max Charging
Current
To configure total charging current for solar and utility chargers.
Max AC
Charging
Current
Set maximum utility charging current
Charging
Source Priority
To configure charger source priority
Back To Grid
Voltage
Set battery voltage to stop discharging when grid is available
Back To
Discharge
Voltage
Set battery voltage to stop charging when grid is available
Enable/Disable
Functions
Overload Auto
Restart
If disabled, the unit won’t be restarted after overload occurs.
Overload
Temperature
Auto Restart
If disabled, the unit won't be restarted after over-temperature fault is
solved.
Overload
Bypass
If enabled, the unit will enter bypass mode when overload occurs.
Beeps While
Primary Source
Interrupt
If enabled, buzzer will alarm when primary source is abnormal.
Buzzer
If disabled, buzzer won’t be on when alarm/fault occurred.
Backlight
If disabled, LCD backlight will be off when panel button is not operated
for 1 minute.
LCD Screen
Return To
Default Display
If selected, no matter how users switch display screen, it will
automatically return to default display screen (Input voltage /output
voltage) after no button is pressed for 1 minute.
Fault Code
If enabled, fault code will be recorded in the inverter when any fault