1
02
AC input voltage range
Appliances
(Default setting)
If selected, acceptable AC input
voltage range will be set to
65-140VAC.
UPS
If selected, acceptable AC input
voltage range will be set to
95-140VAC.
03
Output voltage
110Vac
120V (Default setting)
04
Output frequency
50Hz
60Hz (Default setting)
05
Solar supply priority
Available power will
charge battery first
(default setting)
Solar energy provides power to
charge battery as first priority.
Power supplies the
loads first
Solar energy provides power to the
loads as first priority.
06
Overload bypass:
When enabled, the unit will
transfer to line mode if
overload occurs in battery
mode.
Bypass disabled
Bypass enable (default setting)
07
Auto restart when overload
occurs
Restart disable
(default setting)
Restart enabled
08
Auto restart when over
temperature occurs
Restart disable
(default setting)
Restart enabled
09
Solar energy feed to grid
configuration
WARNING: THIS SETTING
IS NOT
&(57,),(')25
7+(81,7('67$7(6
$/:$<6*(763(&,),&
3(50,66,21)520
<28587,/,7<$1'$+-
7223(5$7(7+,602'(
Feed to grid disable
(default setting)
Solar energy back-feed to grid
disable.
Feed to grid enable
Solar energy back-feed to grid
enable.