EFKA SM210A5710
43
TECHNICIAN LEVEL
Parameter
Designation
Unit
max
min
Preset
Ind.
Prg.
No.
180
itm
0
=
No intermittent operation
2
0
0
A
1
=
Intermittent operation as shown in diagram
(from window 2E onwards) chapter 7.6.2.
2
=
Intermittent operation as shown in diagram
(from window 2E...2A) chapter 7.6.2.
In some operational sequences intermittent stepping
motor operation is not possible, particularly if parallel
operation of the d.c. motor cannot be ensured. In those
cases intermittent operation is automatically suppressed.
181
c10
If in different modes the ratios are displayed for
999
0
3
A
selection by means of the pushbuttons on the control
panel, the stepping motor impulses of parameter 181
are used for intermittent operation.
182
c11
Setting the stepping motor impulses during feeding
999
0
0
A
for intermittent operation, if parameter 180 = 1.
The value of parameter 181 must be subtracted from
the value selected on the control panel. This procedure
is applied in the lockstitch mode during the backtacking
backward section.
190
mbS
0
=
The values of the ratios or steps are selected
1
0
0
A
via inputs in3 and in4. The maximum limit of the
selected values is determined by pressing the
respective pushbuttons on the control panel.
1
=
Inputs in3 and in4 are disabled. Ratios or steps
are selected directly by pressing the respective
pushbuttons on the control panel.