EFKA SM210A5710
20
7.2.3
Timing Diagram1 “Automatic Metering Device at the Seam End“ (Pa. 290=2)
Abbreviation:
SM >>
= Direction of rotation of stepping motor: ccw (speed synchronous with d.c. drive)
SM <<
= Direction of rotation of stepping motor: cw (speed synchronous with d.c. drive)
M3 (BL)
= Blowing
M8 (BM)
= Tape cutter
in1
= Pushbutton for tape cutter
Parameter setting of stepping motor control for above timing diagram:
Sign
Function
Parameter
Mode of operation “automatic metering device at the seam end“
290 = 2
n1
Stepping motor speed for metering device
112
Metering device by means of number of steps
131 = 0
Tape cutter until seam end
143 = 0
+
-
/
1 2
- 2
- 1
0
1
n2
in1
ST1/ 7
ST1/ 27
ST1/ 24
M8
M3
SM
SM
SM
(BM)
(BL)
c1
ST2/ 35
ST2/ 32
ML
FL
ST2/ 21
POS.2
1
DC
ST2/ 20
POS.1
n
0
c2
2 3 1 2 3 4
n12
5
0262/ MODE- 2a
t5
c3
n1
n7
t1