ADD3 all parameters for one STEP
n=type, p=parameters
ADD3 ACW,Voltage,HI-Limit T,LO-Limit T,Ramp Up,Dwell Time,Ramp Down,
Arc Sense,HI-Limit R,LO-Limit R,Offset,Frequency,Arc Dectect,Continuity,
Range,Scanner Setup
SCANNER install,
Scanner Setup
parameter exise
ADD3 DCW,Voltage,Output Polarity,HI-Limit,LO-Limit,Ramp Up,Dwell Time,
Ramp Down,Charge LO,Arc Sense,Offset,Ramp-HI,Arc Dectect,Continuity,
Range,Low Range,Scanner Setup
SCANNER install,
Scanner Setup
parameter exise
ADD3 -DCW,Voltage,HI-Limit,LO-Limit,Ramp Up,Dwell Time,Ramp Down,
Charge LO,Arc Sense,Offset,Ramp-HI,Arc Dectect,Continuity,Range,Low
Range,Scanner Setup
SCANNER install,
Scanner Setup
parameter exise
ADD3 IR,Voltage,Output Polarity,HI-Limit,LO-Limit,Ramp UP,Delay Time,
Dwell Time,Ramp Down,Charge LO,Scanner Setup
SCANNER install,
Scanner Setup
parameter exise
ADD3 GND,Current,Voltage,HI-Limit,LO-Limit,HI-Limit V,LO-Limit V,Dwell
Time,Offset,Offset V,Frequency,Scanner Channel
SCANNER install,
Scanner Channel
parameter exise
ADD3 CONT.,HI-Limit,LO-Limit,Dwell Time,Offset,Scanner Channel
SCANNER install,
Scanner Channel
parameter exise
When Continuity
delay option is off.
LS3? & LS3 nn? Response Data format
Step number,ACW,Voltage,HI-Limit T,LO-Limit T,Ramp UP,Dwell,Ramp Down,
Arc Sense,HI-Limit R,LO-Limit R,Offset,Frequency,Arc Dectect,Continuity,
Range,Scanner Setup
SCANNER install,
Scanner Setup
parameter exise
Step number,DCW,Voltage,Polarity,HI-Limit,LO-Limit,Ramp Up,Dwell Time,
Ramp Down,Charge LO,Arc Sense,Offset,Ramp-HI, Arc Dectect,Continuity,
Range,Low Range,Scanner Setup
SCANNER install,
Scanner Setup
parameter exise
Step number,-DCW,Voltage,HI-Limit,LO-Limit,Ramp Up,Dwell Time,Ramp
Down,Charge LO,Arc Sense,Offset,Ramp-HI, Arc Dectect,Continuity,Range,Low
Range,Scanner Setup
SCANNER install,
Scanner Setup
parameter exise
Step number, IR,Voltage,Polarity,HI-Limit,LO-Limit,Ramp UP,Delay Time,Dwell
Time,Ramp Down,Charge LO,Scanner Setup
SCANNER install,
Scanner Setup
parameter exise
Step number,GND,Current,Voltage,HI-Limit,LO-Limit,HI-Limit V,LO-Limit
V,Dwell Time,Offset,Offset V,Frequency,Scanner Channel
SCANNER install,
Scanner Setup
parameter exise
Step number,CONT.,HI-Limit,LO-Limit,Dwell Time,Offset,Scanner Channel
SCANNER install,
Scanner Channel
parameter exise
When Continuity
delay option is off.