16
4.2 System Parameter Setup
When the output is in OFF condition, press
key to enter into system parameter setup
and SYSTEM indicator will light up. The indication of system parameter setup will be shown at
the Voltage/Frequency display. By pressing the
or
key from the Voltage display, it
then allows to scroll a system parameter setup menu; Power – Up, Frequency HI Limit,
Frequency Low Limit, Voltage HI Limit, Voltage Low Limit and Over Current Fold Back settings.
SYSTEM PARAMETER
FREQUENCY VOLTAGE
CURRENT
English
Explanation
P-UP OFF
Output status of power up.
P-UP On
P-UP LASt
Volt HI 310.0 Maximum voltage setting limit
Volt LO 0.0
Minimum voltage setting limit
FrEq HI 450.0 Maximum frequency setting limit
FrEq LO 40.0 Minimum frequency setting limit
OC Fold OFF
Output Current fold back disable
ON
Output Current fold back enable
1.
Power - Up
While the Voltage display indicates “P-UP”, press the
or
key from the Current display
to select ON/OFF/LAST for the output status. As the Power-Up is turned OFF, the output is set
to be at OFF condition after turn OFF or ON again the AC source. When the Power-Up is ON,
then the output is instantly ON after the AC Power Source is being OFF and ON again. When
the Power-Up is set to LAST, the display will indicate last POWER OFF setting status.
2.
Voltage HI Limit
The Frequency display will indicate “Volt” and the Voltage display shows “HI”. Press the
or
key from the Current display to adjust the high limit voltage within the range of 0 -
310V.
Содержание 6900S Series
Страница 1: ...6900S Series 6905S 6910S 6920S 6930S 6950S AC Power Source User Manual E1 01...
Страница 2: ......
Страница 4: ...Modification history Date Version Content 2017 5 C1 00 First edition...
Страница 6: ......
Страница 13: ...7 6905S rated output current PF 1 6910S rated output current PF 1 6920S rated output current PF 1...
Страница 14: ...8 6930S rated output current PF 1 6950S rated output current PF 1 6950S rated output current PF 0 8...