background image

 
 

14 

 

CHAPTER 4. MANUAL OPERATION 

 

4.1 Manual Operation 

 
1.    Setting Of Output Voltage 

High range voltage can be set between 0 - 310V while low range voltage is 0-155V under 
AC  mode.  Press  and  hold  the 

  or 

  key  will  firstly  clear  the  decimal  number  of 

setting to zero. Subsequently, every 0.3 seconds will change a step and thereafter a first 
integer of setting number will vary and then to the second integer and third integer of the 
voltage setting respectively. For the third integer, it takes 0.1 seconds only to vary every 
step in order to speed up the scrolling.   
 
Press and hold “

︿

”, decimal (clear to 0) → 1

st

 Integer (0.3sec / step) 

→ 

2

nd

 Integer (0.3sec / step) 

→ 

3

rd

 Integer (0.1sec / step)   

 

If the voltage is adjusted when the 

  indicator is ON, the AC Power Source will 

generate the output voltage accordingly.

 

When the voltage display is blinking, the output 

voltage remains the same as the previous set voltage. After 2 second the voltage display 
will stop blinking and the new set voltage is accepted. Any invalid setting may not be 
accepted. 

 
2.    Setting Of Output Frequency 

For  frequency  setting  in  the  range  of  40-99.9  Hz,  each  change  on  the  setting  are 
0.1Hz/step for normal setting and 1Hz/step for coarse setting. In 100-450 Hz range, each 
change on the setting are 1Hz/step for normal setting and 10Hz/step for coarse setting. As 
the 50 Hz or 60 Hz key is pressed, the desired frequency will be immediately updated. (The 
same method applied like voltage setting to scroll the display).   

 
3.    Setting Of Voltage Range 

If the desired voltage is lower than 155 V, press the HI / LO Key first. The LO LED is lighted 
to indicate the AC source is in 0 - 155 Volt range and allow a higher range of current limit. 
For the 0 - 310V of voltage range, the range of current limit drops to half as comparing the 
current limit at the 0 - 155V range (Refer to the specification table). Setting of voltage 
range may not influence the existing output voltage setting. Anyhow, changing the voltage 

range during the 

  indicator is ON will lead to the output voltage cutoff (about 20 

ms) and this should be avoided if possible.   
 

4.    Setting Of Current 

While the OUTPUT is not activated, pressing the 

  or 

  key will enter to the setting 

mode of low-limit current. Press further 

  or 

  key to continue scrolling the display 

in order to change the current limit. If the setting is hold for 2 seconds, it will return to a 
standby mode from current setting mode. Meanwhile, at the standby mode, the output 
capacity (Refer to the specification table) limits the output current or allows setting the 
low limit current. The AC Power Source cuts off the output immediately when the actual 
current has exceeded the limits and a HI-A error message is shown. Any invalid current 
setting will not be accepted   

Содержание 6900S Series

Страница 1: ...6900S Series 6905S 6910S 6920S 6930S 6950S AC Power Source User Manual E1 01...

Страница 2: ......

Страница 3: ...ill void your warranty Operate under non normal contrived omission or accidental calamity including temblor floods rebellion and fire etc Any non authorized modifications tampering or physical damage...

Страница 4: ...Modification history Date Version Content 2017 5 C1 00 First edition...

Страница 5: ...3 2 2 1 Power Requirements 3 2 2 2 Power Cable 3 2 3 Environmental Conditions 4 CHAPTER 3 SPECIFICATIONS 5 3 1 Specification 5 3 2 Front Panel Description 9 3 3 Rear Panel Description 12 CHAPTER 4 MA...

Страница 6: ......

Страница 7: ...oscope probe or using isolated oscilloscope To prevent accidental injury or death these safety procedures must be strictly observed when handling and using the test instrument 1 3 Service and Maintena...

Страница 8: ...user modifications will void your warranty EEC will not be responsible for any injuries sustained due to unauthorized equipment modifications or use of parts not specified by EEC Instruments returned...

Страница 9: ...uirements This instrument requires a power source of 110 volts AC 10 50 60 Hz single phase or 220 volts AC 10 50 60 Hz single phase Please check the rear panel to be sure the proper switch setting is...

Страница 10: ...l packaging materials that you originally received If you are returning your instrument to us for servicing please repackage the instrument in its original container Please enclose the instrument with...

Страница 11: ...oad Crest Factor 3 Line Regulation 0 1V Load Regulation 0 5 of output 0 5V at Resistive Load SETTING Voltage Range 0 310V 155 310V Auto Range Resolution 0 1V Accuracy 1 of setting 0 1 f s 1 of setting...

Страница 12: ...ack On Off Setting On when output current over setting Hi A value it will fold back output voltage to keep constant output current is setting Hi A value Response time 1 4s Efficiency 78 80 Protection...

Страница 13: ...7 6905S rated output current PF 1 6910S rated output current PF 1 6920S rated output current PF 1...

Страница 14: ...8 6930S rated output current PF 1 6950S rated output current PF 1 6950S rated output current PF 0 8...

Страница 15: ...5 UNIVERSAL AC OUTPUT SOCKET Trip Current 20A 6 P PF SELECT BUTTON Select the display of output wattage or power factor value 7 M1 M2 AND M3 BUTTON Store setting memories Press and hold for a second o...

Страница 16: ...ss to set the output frequency to 60 Hz 16 50 Hz KEY Press to set the output frequency to 50 Hz 17 POWER FACTOR INDICATOR When the LED is ON the display shows the output power factor 18 WATTMETER INDI...

Страница 17: ...ge 25 LO INDICATOR When the LED is lit the output is set to low range 26 INDICATOR When the LED is lit it is at normal operation whereas when the LED is blinking it is at abnormal operation 27 POWER S...

Страница 18: ...12 3 3 Rear Panel Description 6905S rear panel 6910S rear panel 6920S rear panel 1 1 2 2 3 3 4 5 5 6 8 8 1 2 6 7 8...

Страница 19: ...LE Standard IEC 320 connector for connection to a standard NEMA style line power mains cord 5 INPUT POWER SWITCH Line voltage selection is set by the position of the switch In the left position it is...

Страница 20: ...rmal setting and 10Hz step for coarse setting As the 50 Hz or 60 Hz key is pressed the desired frequency will be immediately updated The same method applied like voltage setting to scroll the display...

Страница 21: ...arm an error message is indicated 7 Front Panel Lockout Press the key will lead to the LOCK indicator to be lit in order to disable all keys on the front panel except PF P key Further pressing the key...

Страница 22: ...m voltage setting limit FrEq HI 450 0 Maximum frequency setting limit FrEq LO 40 0 Minimum frequency setting limit OC Fold OFF Output Current fold back disable ON Output Current fold back enable 1 Pow...

Страница 23: ...n becomes 1HZ STEP 5 Frequency Low Limit The Frequency display will indicate FrEq and the Voltage display shows LO Press the or key from the Current display to adjust the low limit frequency within th...

Страница 24: ...s will show the overloaded voltage or current respectively They will occur Over Current Protection that output circuit is short and the system will self protect within 1 second or the output current h...

Страница 25: ...ent displays will show the overloaded voltage or current respectively If the Amplifier is fault or abnormal or GBIT on the Amplifier is burned the Frequency display will indicate A SH and the alarm wi...

Страница 26: ...will indicate a necessary value needed to be calibrated Using the voltage value from the RMS Voltmeter press or key from the Current display to scroll the display which indicate the current voltage va...

Страница 27: ...ey to save the data stored and the low range current calibration is completed High Range Current Calibration Press or key from the Frequency display to select A HI Connect a variable resistor as load...

Страница 28: ...or key from the Frequency display to select P HI Connect a variable resistor as load and a calibrated true RMS Power Meter on one of the output socket and press key in order to activate the CPU to re...

Страница 29: ...ce with the input circuit and all related parts are required to be checked and calibrated at least once every year This is to protect user in terms of safety and to ensure a high accuracy of this AC P...

Отзывы: