SSM-LE Series
Operations Manual
Eberle Design Inc.
Page 26
Pin
Function
I/O
U
Start-Delay Relay Closed
(Open during Start Delay period)
[O]
V
Channel 10 Red
[I]
W
Spare 4
[-]
X
Spare 5
[-]
Y
Spare 6
[-]
Z
Channel 3 Red
[I]
a
Red Enable
[I]
b
Spare 7
[-]
c
Spare 8
[-]
8.2 SSM-6LE HARNESSING CONNECTOR
This Military Specification MIL-C-26482 connector is interchangeable with 6 channel
monitors as defined by NEMA Traffic Control Systems Specification TS1-1989 R2005, part
6. Connector MS-A will intermate with a MS 3116 22-55 SY.
8.2.1 SSM-6LE CONNECTOR MS-A PIN TERMINATIONS
Pin
Function
I/O
A
AC Line I
[I]
B
AC Line II
[I]
C
Output Relay 1 Open (Stop Time, Closes
when fault occurs)
[O]
D
Output Relay 2 Closed (FTR Drive, Opens
when fault occurs)
[O]
E
Start-Delay Relay Open
(Closes during Start Delay period)
[O]
F
Channel 6 Green
[I]
G
Channel 6 Red
[I]
H
Channel 5 Green
[I]
J
Channel 4 Green
[I]
K
Channel 4 Red
[I]
L
Channel 3 Green
[I]
M
Channel 2 Green
[I]
N
Channel 2 Red
[I]
P
Channel 1 Green
[I]
R
Red Enable
[I]
S
+24V Monitor I
[I]
T
Logic Ground
[-]
U
Chassis Ground
[-]
V
AC Neutral
[-]
W
Cabinet Interlock B
[-]
X
Output Relay 1 Common (Stop Time)
[I]
Y
Output Relay 2 Common (FTR Drive)
[I]
Z
Output Relay 2 Open