SSM-LE Series
Operations Manual
Eberle Design Inc.
Page 24
Section 8
Wiring Assignments
8.1 SSM-12LE HARNESSING CONNECTORS
These Military Specification MIL-C-26482 connectors are interchangeable with 12 channel
monitors as defined by NEMA Traffic Control Systems Specification TS1-1989 R2005, part
6. Connector MS-A will intermate with a MS 3116 22-55 SZ. Connector MS-B will intermate
with a MS 3116 16-26 S.
8.1.1 SSM-12LE CONNECTOR MS-A PIN TERMINATIONS
Pin
Function
I/O
A
AC Line
[I]
B
Output Relay 1 Open (Stop Time, Closes
when fault occurs)
[O]
C
Output Relay 2 Closed (FTR Drive, Opens
when fault occurs)
[O]
D
Channel 12 Green
[I]
E
Channel 11 Green
[I]
F
Channel 10 Green
[I]
G
Channel 9 Green
[I]
H
Channel 8 Green
[I]
J
Channel 7 Green
[I]
K
Channel 6 Green
[I]
L
Channel 5 Green
[I]
M
Channel 4 Green
[I]
N
Channel 3 Green
[I]
P
Channel 2 Green
[I]
R
Channel 1 Green
[I]
S
+24 Monitor I
[I]
T
Logic Ground
[I]
U
Earth Ground
[I]
V
AC Neutral
[I]
W
Output Relay 1 Common (Stop Time)
[I]
X
Output Relay 2 Common (FTR Drive)
[I]
Y
Channel 12 Yellow
[I]
Z
Channel 11 Yellow
[I]
a
Channel 10 Walk
[I]
b
Channel 10 Yellow
[I]
c
Channel 9 Yellow
[I]
d
Channel 8 Yellow
[I]
e
Channel 7 Yellow
[I]
f
Channel 6 Yellow
[I]
g
Channel 5 Yellow
[I]
h
Channel 3 Yellow
[I]
i
Channel 3 Walk
[I]
j
Channel 2 Yellow
[I]