SSM-LE Series
Operations Manual
Eberle Design Inc.
Page 25
Pin
Function
I/O
k
Channel 1 Yellow
[I]
m
Controller Voltage Monitor
[I]
n
+24V Monitor Inhibit
[I]
p
Output Relay 1 Closed (Stop Time, Opens
when fault occurs)
[O]
q
Output Relay 2 Open (FTR Drive, Closes
when fault occurs)
[O]
r
Channel 12 Walk
[I]
s
Channel 11 Walk
[I]
t
Channel 9 Walk
[I]
u
Channel 8 Walk
[I]
v
Channel 7 Walk
[I]
w
Channel 5 Walk
[I]
x
Channel 4 Yellow
[I]
y
Channel 2 Walk
[I]
z
Channel 1 Walk
[I]
AA
Spare 1
[-]
BB
Reset
[I]
CC
Cabinet Interlock A
[I]
DD
Cabinet Interlock B
[O]
EE
Channel 6 Walk
[I]
FF
Channel 4 Walk
[I]
GG
Spare 2
[-]
HH
Spare 3
[-]
8.1.2 SSM-12LE CONNECTOR MS-B PIN TERMINATIONS
Pin
Function
I/O
A
AC Line II
[I]
B
Start-Delay Relay Common
[I]
C
Start-Delay Relay Open
(Closes during Start Delay period)
[O]
D
Channel 12 Red
[I]
E
Channel 11 Red
[I]
F
Channel 9 Red
[I]
G
Channel 8 Red
[I]
H
Channel 7 Red
[I]
J
Channel 6 Red
[I]
K
Channel 5 Red
[I]
L
Channel 4 Red
[I]
M
Channel 2 Red
[I]
N
Channel 1 Red
[I]
P
Spare 1
[-]
R
+24V Monitor II
[I]
S
External Watchdog (Spare 2)
[-]
T
Spare 3
[-]