25
Natural Gas (NG) Installation and Requirements:
•
Ensure that the natural gas supply line is fitted with a shut-off valve that can be easily accessed in
the event that shutoff at the source is required.
• Grills operated with NG fuel must be installed with the NG regulator supplied with your EdgeStar
grill.
• EdgeStar NG grills are equipped with an NG regulator set to 4 inches water column. This
regulator is for NG only.
•
The standard fitting connector for an NG supply is 1/2”.
•
Use a quality natural gas flex connector (not included) to mate to the included NG regulator. CSA,
UL, or ETL certified connecting lines are recommended. Stainless steel flex connectors are also
recommended.
•
The flex connector should be an appropriate length for your setup. Do not use a connector that is
too short and requires you to stretch it too far to make the connection.
•
Flex connectors should come with a standard ½” connection for NG fittings.
•
Flex connectors should be placed carefully in a location where they are not at risk of being cut,
punctured, or kinked.
•
Yellow Teflon pipe thread sealant (PTFE tape) is recommended for use on all pipe thread
connections with the exception of flared threads, which will have a secure connection.
To Connect the NG Gas Supply:
1.
Ensure the NG shut-off valve is fully closed. You should not hear a hissing noise or smell natural
gas.
2.
All gas control (burner) knobs must be in the off position.
3.
Fasten the ½” flex connector – already installed to the NG supply shut-off valve – to the included
NG regulator. Use Yellow Teflon pipe thread sealant (PTFE tape) for non-flared connections. No
sealant is required for flared connections.
Do not overtighten the regulator connection
as it
may cause damage or strip the threading.
4.
Open the NG shut-off valve.
5.
Using a soapy water mixture in a spray bottle, check for leaks at all joints and connection points.
Bubbles should not form in the soapy water mixture. See the section titled,
“Checking for Gas
Leaks”
in this manual for further instructions and details.
6.
Once you have confirmed that all connections are secure and there are no gas leaks, you may
proceed with normal use of your grill. All connection points must be free from gas leaks before
first use of the gas grill.
7.
A reminder to always close the shut-off valve when the grill is not in use.
Содержание GRL270IBLP
Страница 9: ...9 Parts Identification GRL270IBNG GRL270IBLP GRL300IBNG GRL300IBLP Two Burner Gas Grills ...
Страница 11: ...11 GRL360IBBNG GRL360IBBLP GRL420IBBNG GRL420IBBLP Three Burner Gas Grills ...
Страница 14: ...14 GRL300IBNG GRL300IBLP 26 1 2 10 3 8 28 1 16 30 25 5 8 36 1 2 2 1 2 21 1 2 10 3 8 Front Back Left Right ...
Страница 15: ...15 GRL360IBBNG GRL360IBBLP 36 25 5 8 28 1 16 32 9 16 10 3 8 36 1 2 2 1 2 21 1 2 10 3 8 Front Back Left Right ...
Страница 16: ...16 GRL420IBBNG GRL420IBBLP 42 25 5 8 28 1 16 38 9 16 10 3 8 36 1 2 2 1 2 21 1 2 10 3 8 Front Back Right Left ...
Страница 50: ...www edgestar com 2021 EdgeStar ...