01/05
P/N 120413
15
User’s Manual
Installation
Banner Engineering Corp.
• Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
Strobe Out
Strobe Out is Pin 4 of the light connector. When Strobe Out is enabled, the Sensor generates a strobed output signal upon
receiving a valid trigger. The type of signal may be configured as shown below:
Level (default: Active High)
Active High:
Use if the light is enabled at 5V
Active Low:
Use if the light is enabled at 0V
Strobe Width (default: Time Duration)
ON:
ON continuously
OFF:
OFF continuously
Exposure:
Active signal during the exposure time
Time Duration:
Strobe is active upon a valid trigger, with length set from 1 to 10,000 ms
Electrical Specifications of Strobe
High:
4V min. at 100 mA max.
Low:
0.5V max. at 100 microamps max.
---------------------------------------------------------------------------
RS-232, Pins 1, 9, 10, and 11
The RS-232 port is used to export runtime information in ASCII format. For information on how to configure the serial
connection, see
Section 8, Exporting with the Communication Tool
--------------------------------------------------------------------------
Sensor Cable
to
PC Serial Port
Pin 1 (yellow wire), transmit data
to
Pin 2, receive data
Pin 9 (violet wire), receive data
to
Pin 3, transmit data
Pin 10 (green wire), signal ground
to
Pin 5, signal ground
Pin 11 (blue wire), dc common
to
Pin 5, signal ground