Exporting with the Communication Tool
Banner Engineering Corp.
• Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
Telnet Command Window
Testing Ethernet or Serial Communications with HyperTerminal
The following table provides HyperTerminal testing instructions for both Ethernet and Serial communications.
HyperTerminal Testing for Ethernet and Serial
--------------------------------------------------------------------
-------------------------------------------------------------
Sample HyperTerminal Run Time Results
Ethernet
Serial
1.
Start an inspection that has a configured Communication tool.
2.
Connect a PC to the Sensor using an Ethernet crossover cable.
Connect a PC to the Sensor using a serial cable.
3.
Start a new connection with HyperTerminal.
4.
Connect using TCP/IP (Winsock).
Connect using COM1 (choose a serial COM port).
5.
Configure HyperTerminal to talk with the Sensor.
Example:
-
Host Address = 192.168.0.1 (Sensor default)
-
Port number = 20000 (Ethernet Socket 1)
Configure HyperTerminal to talk with the Sensor.
Example:
-
Baud rate = 115200 bits/sec (Sensor default)
-
Data bits = 8 (Sensor default)
-
Parity = None (Sensor default)
-
Stop bits = 1 (Sensor default)
-
Flow control = None
NOTE: The Sensor settings must match exactly with the PC.
6.
Trigger the Sensor.
7.
View the results.