27
y
Check that the room temperature is not above +38 ºC, the appliance's maximum operating
temperature (for Plus + 43 ºC).
y
Check that the goods load is perfectly positioned and does not obstruct the outlets of the
inner fan, and that the time it has been inside is sufficient to cool the products.
y
Check that the doors close properly.
y
Check that the condenser is clean: You must bear in mind that the cleaner the refrigerator is
the greater the energy saving, particularly the condenser’s ribbing. The frequency of this
cleaning will be determined by the characteristics of the premises. If it is dirty, call the
technical support service to clean it.
Clean condenser
c) In the event of strange or excessive noise
y
Check the unit's levelling and that the doors close properly.
y
Check that there are no objects touching any of the refrigerator's moving components.
9.2
Special maintenance
(Authorised technical personnel)
y
Condenser cleaning: When cleaning, be careful not to bend the condenser aluminium ribs, as
on the contrary the air will not come through and will not condense, causing serious damage
to the appliance and its repair guarantee will be made void.
y
Check that the premise's temperature does not exceed that indicated for your cabinet.
y
The guarantee will be made void if there is insufficient ventilation.
y
Check that the doors close properly.
y
Do not disassemble the mobile components guards without first having turned the appliance
off.
y
Take all the necessary precautions before accessing the area of the condenser unit, given the
existence of high temperatures of some components, with the resulting risk of burns.
y
If the flexible power cable or cord is damaged, it must be replaced by the manufacturer,
after-sales service or authorised technical personnel in order to prevent risks.
y
It if is replaced, the earth pin must be positioned again.
y
If you need to change a cable, you must never use a smaller section.
y
The electrical connections are carried out with 6.35 mm Faston terminals, protected with
covers.
y
If it is necessary to disassemble the inner lid of the control panel’s electrical installation, it is
extremely important to leave it exactly as it was when reassembling it.
Содержание AA-140x-C
Страница 14: ...13 PATISSERIE xARPA 701 760 729 2005 PLUS xAPRG 701 xAPCG 701 653 796 1996 xAPRG 1402 xAPCG 1402 1318 796 1996...
Страница 15: ...14 DIMENSIONS DE L EMPLACEMENT DU CONDUIT D VACUATION D URGENCE...
Страница 24: ...23 EMERGENCY DRAINAGE INSTALMENT MEASUREMENTS...
Страница 33: ...32 MEDIDAS DA COLOCA O DE DRENAGEM DE EMERG NCIA...
Страница 42: ...41 MISURE PER IL MONTAGGIO DELLO SCARICO DI EMERGENZA...