Internal connection        External wired connection 

 

DIP 1: ON 

DIP 2: OFF 

Only  the  internal  contact  will  be 

active. 

DIP 1: OFF 

DIP 2: ON 

Only  the  external  contacts  will  be 

active. 

DIP 1: ON 

DIP 2: ON 

Both  contacts  will  be  active.  (Both 

contacts  must  be  all  close,  the 

Detector will then be treated as close; 

if  one  of  the  contacts  is  open,  the 

Detector will be treated as open.) 

DIP 1: OFF 

DIP 2: OFF 

Only the internal contact will be 

active. 

 

Note: Remove batteries before setting the SW2.    Refit   

batteries after setting the SW2. 

 

3.    In  order  to  communicate  with  the  Control  Panel, 

the ID code of the Detector needs to be learned by 

the  Control  Panel.  By  pressing  the  tamper  switch   

located  at  the  rear  cover  of  the  Detector  will  emit 

the ID code to the Control Panel instantly, subject 

to  the  Control  Panel  being  set  at  the  ID  code 

learning mode. 

 
TESTING THE DOOR/WINDOW CONTACT 
DETECTORS 

 
Ensure the system is in test mode. 
 

1.    Detach or close the magnet from the Detector, the           

      Control  Panel  will  ding  dong  to  indicate  that  the 

alarm signal has been received.   

 

2.  Press 

  to exit test mode. 

 

 

 

 

FACTORY DEFAULTS 

 

Disarm Mode 

Disarm 

User Access Code 

1 2 3 4 

Key Tone 

On (enable) 

Activation Type 1 

Siren/Dialer enable 

Alarm Duration 

1 minute 

Jamming Detection 

Off (disable) 

Entry Delay 15 sec 

for arm/part-arm 

Off (disable) 

 

SETTING 

 

 

     

Q. Dip Switch 

R. Jumper Link 

 

JUMPER LINK 

Setting Jumper link into the ON position will reset all of 

the settings to factory default, such as all of ID codes, 

phone number and alarm message. 

DEFAULT

                   

RESET

 

                                        TOP VIEW 

 

Содержание HA700

Страница 1: ...stallation Operating Manual Fixing pack Control Panel 4 x 1 5V LR20 size D cell battery or 9V DC adapter option Motion Sensor 3 x 1 5V AA size battery option Door Window Contact Detector 3 x 1 5V AAA...

Страница 2: ...EM ZONING The detector s may be set to operate on either Zone 1 Zone 2 or panic For ease of alarm verification it is recommended that the Zones are arranged logically eg downstairs detectors on Zone 1...

Страница 3: ...rn their codes individually for the system to operate correctly For the Motion and Door Window Contact Detectors simply pressing the tamper switch located adjacent to the PCB will emit the ID code to...

Страница 4: ...y Use this as a guide for your installation in conjunction with the recommendations contained in this manual for planning your intruder alarm system Before attempting to install your Alarm System it i...

Страница 5: ...ss keypad whereas Panic zone press keypad on the Control Panel Note It is recommended that the smoke detector and flood detector are assigned to panic zone For wireless keypad press the tamper switch...

Страница 6: ...screw on the metal mounting bracket completely 2 Use one finger from each hand to remove the battery cover from the rear of Control Panel 3 Fit 4 batteries to the battery compartment and ensure corre...

Страница 7: ...7 down the Control Panel to get into the L shaped metal mounting bracket 8 Tighten the screw on the L shaped metal mounting bracket to secure the Control Panel...

Страница 8: ...2 Under standby mode LED Sound Status Low Battery Zone 1 Zone 2 Panic Initial power up One long beep Green LED on for 3 seconds Jamming Alarm Rapid flash 3 times every 3 seconds 1 5 Zone Trigger 1 2...

Страница 9: ...Disarm the system The Remote Controller also incorporates a Panic switch Activating the Panic switch will immediately initiate a Full Alarm condition whether the system is Armed or Disarmed unless the...

Страница 10: ...n infra red radiation levels caused when a person moves within or across the devices field of vision If movement is detected an alarm signal will be emitted Note Motion Sensors will also detect animal...

Страница 11: ...the sensor in a position where it is subject to excessive vibration 6 Ensure that the position selected for the motion sensor is within effective range of the Control Panel Note When the system is ar...

Страница 12: ...n of the sensor to be checked during installation without triggering a Full Alarm ON Walk Test mode OFF Normal mode Note Remove batteries before setting the SW2 Refit batteries after setting the SW2 N...

Страница 13: ...senses movement the LED behind the lens will flash In addition the Control Panel will ding dong If necessary adjust the detection range by changing the mounting position of the PCB within the sensor h...

Страница 14: ...ED on the Detector will illuminate 4 Using the rear cover as a template mark the positions of fixing holes on the fixed part of the frame along the opening edge opposite the hinges using screws provid...

Страница 15: ...er switch located at the rear cover of the Detector will emit the ID code to the Control Panel instantly subject to the Control Panel being set at the ID code learning mode TESTING THE DOOR WINDOW CON...

Страница 16: ...There is a row of 8 DIP switches These switches set the House Code for the Control Panel and must be set to the same ON OFF combination as the House Code DIP switches in the wireless siren 1 2 3 4 5 6...

Страница 17: ...s User access code When full alarm condition occurs disarm the alarm using remote controller wireless keypad or the keypad on the Control Panel as mentioned above RECORDING ALARM MESSAGE Press User ac...

Страница 18: ...e which zone the detector should be assigned Users have a 6 second to input zone number If the detector is to be assigned in Zone 1 press keypad Zone 2 press keypad whereas Panic zone press keypad on...

Страница 19: ...conds the Control Panel will emit system on system off command to the wireless siren During test mode press keypad more than 3 seconds the Control Panel will only dial up the first preset phone number...

Страница 20: ...ength of selecting entry delay for on or off is 15 seconds Press for on Press for off If 15 seconds expires or a sequence of incorrect input is entered 3 times the Control Panel will exit this mode of...

Страница 21: ...ol Panel Control Panel Press more than 3 seconds will generate full alarm condition Remote Controller Slide the Panic switch upwards The alarm will continue either for the alarm duration or until the...

Страница 22: ...into Test mode before removing the Control Panel from the mounting bracket and disconnecting the power supply BATTERIES Before removing the battery cover on any device to replace the battery ensure th...

Страница 23: ...23...

Отзывы: