15
Internal connection External wired connection
DIP 1: ON
DIP 2: OFF
Only the internal contact will be
active.
DIP 1: OFF
DIP 2: ON
Only the external contacts will be
active.
DIP 1: ON
DIP 2: ON
Both contacts will be active. (Both
contacts must be all close, the
Detector will then be treated as close;
if one of the contacts is open, the
Detector will be treated as open.)
DIP 1: OFF
DIP 2: OFF
Only the internal contact will be
active.
Note: Remove batteries before setting the SW2. Refit
batteries after setting the SW2.
3. In order to communicate with the Control Panel,
the ID code of the Detector needs to be learned by
the Control Panel. By pressing the tamper switch
located at the rear cover of the Detector will emit
the ID code to the Control Panel instantly, subject
to the Control Panel being set at the ID code
learning mode.
TESTING THE DOOR/WINDOW CONTACT
DETECTORS
Ensure the system is in test mode.
1. Detach or close the magnet from the Detector, the
Control Panel will ding dong to indicate that the
alarm signal has been received.
2. Press
to exit test mode.
FACTORY DEFAULTS
Disarm Mode
Disarm
User Access Code
1 2 3 4
Key Tone
On (enable)
Activation Type 1
Siren/Dialer enable
Alarm Duration
1 minute
Jamming Detection
Off (disable)
Entry Delay 15 sec
for arm/part-arm
Off (disable)
SETTING
Q. Dip Switch
R. Jumper Link
JUMPER LINK
Setting Jumper link into the ON position will reset all of
the settings to factory default, such as all of ID codes,
phone number and alarm message.
DEFAULT
RESET
TOP VIEW
Содержание HA700