11
PCB Position
Range
1
10m
3
7m
5
5m
When considering and deciding upon the mounting
position for the sensor the following points should be
considered to ensure trouble free operation:
1.
Do not locate the sensor facing a window or where
it is exposed to or facing direct sunlight. Motion
Sensors are not suitable for use in conservatories.
2.
Do not locate the sensor where it is exposed to
ventilators.
3.
Do not locate the sensor directly above a heat
source, (e.g. fire, radiator, boiler, etc).
4.
Where possible, mount the sensor in the corner of
the room so that the logical path of an intruder
would cut across the fan detection pattern.
Motion Sensors respond more effectively to
movement across the device than to movement
directly towards it.
Less Sensitive More Sensitive
5.
Do not locate the sensor in a position where it is
subject to excessive vibration
6.
Ensure that the position selected for the motion
sensor is within effective range of the Control
Panel.
Note: When the system is armed, household pets
should not be allowed into an area protected by a
motion sensor as their movement would trigger the
motion sensor and generate an alarm.
INSTALLING THE MOTION SENSORS
Ensure that the system is in Test Mode.
1. Undo and remove the fixing screw from the bottom
edge of the Motion Sensor. Carefully pull the
bottom edge of the sensor away from the rear
cover and then slide down to release the top clips.
2. Carefully drill out the required mounting holes in
the rear cover using 3mm drill according to whether
the unit is being mounted in a corner or against a
flat wall.
Note: Using 1
st
mounting hole to fulfill corner
mounting installation, while 2
nd
mounting hole for
flat wall installation.
1
2
3
4
5
5
4
3
2
1
1st Mounting Hole Positions
2nd Mounting Hole Positions
Содержание HA700