TESTING THE SYSTEM 

 

With the Control Panel in Disarm Mode 

 

Press 

 

 

 

 

 

 

                 

  User access code 

to enter test mode. 

 

1.  Trigger  each  detector  on  the  system  by  either 

walking  into  a  Motion  Sensor  protected  area  or 

by  opening  a  door/window  protected  by  a 

Door/Window  Contact  detector.    As  each 

detector  is  triggered  the  Control  Panel  will  ding 

dong  to  indicate  that  an  alarm  signal  has  been 

received. 

 

2.  Operate  detector  tamper  switches  by  opening 

the  case  of  the  device.    As  the  switches  are 

operated the Control Panel will ding dong.   

 

3.  Activate each button on the Remote Controller in 

turn.    As  each  button  is  pressed  the  Control 

Panel will ding dong. 

 

4.    Press 

  3 seconds on the Control Panel, if 

the wireless siren emits one long beep, the 

wireless siren enters ‘system off’ mode, which 

offers the flexibility of removing or changing 

siren’s battery without triggering a full alarm 

condition.   

 

 

Press 

  3 seconds on the Control Panel, if 

the  wireless  siren  emits  one  long  and  two  short 

beeps,  the  wireless  siren  enters  ‘system  on’ 

mode.    A full alarm condition will occur. 

 

To  get  back  to  the  normal  mode,  press 

  on  the 

Control Panel to exit test mode. 

 

MOTION SENSORS 

 

Motion Sensors are designed to detect movement in a 

protected  area  by  detecting  changes  in  infra-red 

radiation levels caused when a person moves within or 

across  the  devices  field  of  vision.    If  movement  is 

detected an alarm signal will be emitted. 

 

Note:  Motion  Sensors  will  also  detect  animals,  so 

ensure  that  pets  are  not  permitted  access  to  areas 

fitted with Motion Sensors when the system is armed. 

 

The  Motion  Sensor  adopts  3  AA  size  1.5V  battery 

which  under  normal  conditions  will  have  typical  life  in 

excess  of  1  year.    When  the  battery  level  drops,  with 

the Motion Sensor in normal mode and the rear cover 

fitted,  the  LED  behind  the  detection  window  will  flash 

upon  detecting  movement.    When  this  occurs  the 

batteries should be replaced as soon as possible. 

Note:  The  adoption  of  alkaline  battery  is  highly 

recommended. 

 

CHOOSING A MOUNTING LOCATION 

 

The  Motion  Sensor  is  suitable  for  mounting  in  dry 

interior locations only. 

 

The  recommended  position  for  a  Motion  Sensor  is  in 

the corner of a room mounted at a height between 1.8 

and  2m.    At  this  height,  the  sensor  will  have  a 

maximum range of up to 10m with a field of view of 110

°

, subject to the position for the PCB being set in 1. The 

position  of  the  PCB  inside  the  Motion  Sensor  can  be 

set  to  5  different  positions  to  adjust  the  range  of  the 

detector.  Setting the PCB  in position 3  will reduce the 

range to 7m approximately, with position 5 providing a 

range  of  5m  approximately.    The  recommended 

position setting for the PCB is in position 1. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110°

10M

U

9

1

3

5

7

Содержание HA700

Страница 1: ...stallation Operating Manual Fixing pack Control Panel 4 x 1 5V LR20 size D cell battery or 9V DC adapter option Motion Sensor 3 x 1 5V AA size battery option Door Window Contact Detector 3 x 1 5V AAA...

Страница 2: ...EM ZONING The detector s may be set to operate on either Zone 1 Zone 2 or panic For ease of alarm verification it is recommended that the Zones are arranged logically eg downstairs detectors on Zone 1...

Страница 3: ...rn their codes individually for the system to operate correctly For the Motion and Door Window Contact Detectors simply pressing the tamper switch located adjacent to the PCB will emit the ID code to...

Страница 4: ...y Use this as a guide for your installation in conjunction with the recommendations contained in this manual for planning your intruder alarm system Before attempting to install your Alarm System it i...

Страница 5: ...ss keypad whereas Panic zone press keypad on the Control Panel Note It is recommended that the smoke detector and flood detector are assigned to panic zone For wireless keypad press the tamper switch...

Страница 6: ...screw on the metal mounting bracket completely 2 Use one finger from each hand to remove the battery cover from the rear of Control Panel 3 Fit 4 batteries to the battery compartment and ensure corre...

Страница 7: ...7 down the Control Panel to get into the L shaped metal mounting bracket 8 Tighten the screw on the L shaped metal mounting bracket to secure the Control Panel...

Страница 8: ...2 Under standby mode LED Sound Status Low Battery Zone 1 Zone 2 Panic Initial power up One long beep Green LED on for 3 seconds Jamming Alarm Rapid flash 3 times every 3 seconds 1 5 Zone Trigger 1 2...

Страница 9: ...Disarm the system The Remote Controller also incorporates a Panic switch Activating the Panic switch will immediately initiate a Full Alarm condition whether the system is Armed or Disarmed unless the...

Страница 10: ...n infra red radiation levels caused when a person moves within or across the devices field of vision If movement is detected an alarm signal will be emitted Note Motion Sensors will also detect animal...

Страница 11: ...the sensor in a position where it is subject to excessive vibration 6 Ensure that the position selected for the motion sensor is within effective range of the Control Panel Note When the system is ar...

Страница 12: ...n of the sensor to be checked during installation without triggering a Full Alarm ON Walk Test mode OFF Normal mode Note Remove batteries before setting the SW2 Refit batteries after setting the SW2 N...

Страница 13: ...senses movement the LED behind the lens will flash In addition the Control Panel will ding dong If necessary adjust the detection range by changing the mounting position of the PCB within the sensor h...

Страница 14: ...ED on the Detector will illuminate 4 Using the rear cover as a template mark the positions of fixing holes on the fixed part of the frame along the opening edge opposite the hinges using screws provid...

Страница 15: ...er switch located at the rear cover of the Detector will emit the ID code to the Control Panel instantly subject to the Control Panel being set at the ID code learning mode TESTING THE DOOR WINDOW CON...

Страница 16: ...There is a row of 8 DIP switches These switches set the House Code for the Control Panel and must be set to the same ON OFF combination as the House Code DIP switches in the wireless siren 1 2 3 4 5 6...

Страница 17: ...s User access code When full alarm condition occurs disarm the alarm using remote controller wireless keypad or the keypad on the Control Panel as mentioned above RECORDING ALARM MESSAGE Press User ac...

Страница 18: ...e which zone the detector should be assigned Users have a 6 second to input zone number If the detector is to be assigned in Zone 1 press keypad Zone 2 press keypad whereas Panic zone press keypad on...

Страница 19: ...conds the Control Panel will emit system on system off command to the wireless siren During test mode press keypad more than 3 seconds the Control Panel will only dial up the first preset phone number...

Страница 20: ...ength of selecting entry delay for on or off is 15 seconds Press for on Press for off If 15 seconds expires or a sequence of incorrect input is entered 3 times the Control Panel will exit this mode of...

Страница 21: ...ol Panel Control Panel Press more than 3 seconds will generate full alarm condition Remote Controller Slide the Panic switch upwards The alarm will continue either for the alarm duration or until the...

Страница 22: ...into Test mode before removing the Control Panel from the mounting bracket and disconnecting the power supply BATTERIES Before removing the battery cover on any device to replace the battery ensure th...

Страница 23: ...23...

Отзывы: