be only one anode type throughout. Magnesium anodes must never be used with Eddyfi Technologies
equipment.
Because many of the chassis parts are electrically isolated, the anodes provide protection by proximity
rather than by direct conductive contact. Anodes are installed onto the Magg™ 480 as illustrated below
with Loctite 243 (blue). In some cases, the Spectrum™ 90 or Spectrum™ 120 cameras may be partly
equipped with anodes. Refer to the Spectrum™ 90 or Spectrum™ 120 manuals for anode placement on
the Spectrum cameras. Contact your sales representative for anode replacements.
Rinsing and Cleaning
After every mission check to see if the vehicle needs cleaning.
1. If the system has been used in salt water, thoroughly rinse the vehicle with fresh water prior to
being stored away. Accelerated corrosion will result if the inspection system is not rinsed
properly. Pay close attention to rinsing and cleaning the camera window, LED light dome and the
spaces between moving parts and track belts.
2. Use an open hose or tap at regular water line pressure for rinsing. Do not pressure wash the
equipment
– water will be forced into the camera at these high pressures.
3. Avoid scratching the camera port. Use glass cleaner and a soft cloth to clean the port.
CAUTION:
Do not use a pressure washer to clean the camera. Very high-
pressure water can push past seals and flood the components resulting in
electrical damage or personal injuries.