background image

 

 

2569 Kenworth Road, Suite C 

Nanaimo, BC, V9T 3M4 

CANADA 

 

+1.250.729.8080 

[email protected]  

www.eddyfitechnologies.com  

 

 

 

 

 

 

 

INUKTUN 

MAGGHD™  

 

 

Содержание INUKTUN MAGGHD

Страница 1: ...2569 Kenworth Road Suite C Nanaimo BC V9T 3M4 CANADA 1 250 729 8080 info eddyfitechnologies com www eddyfitechnologies com INUKTUN MAGGHD...

Страница 2: ...on and Directives 6 Safety 6 Intended Use 9 Laser Lines 10 MaggHD Vehicle 11 Dimensions 11 System Power 12 Power Requirements 12 Generators Inverters 12 Galvanic Corrosion Control 12 System Setup 12 P...

Страница 3: ...ection Error Bookmark not defined Using the UT Probe Error Bookmark not defined Operation 20 Tether Handling 20 Connector Handling 20 SubConn Connector Lubrication and Cleaning 21 Impulse Connector Lu...

Страница 4: ...Revision A08 Created by KJB Date 26 Sep 2019 3080885 A08 Source Location C ePDM ISLEng products au micromag manuals UMAU015088 docm Page 4 of 29 User Manual Product System Drawing Package Availabilit...

Страница 5: ...s This manual copyright 2019 by Inuktun Services Ltd All rights reserved Description The Inuktun MaggHD is a magnetic tracked crawler capable of driving vertically or inverted along ferrous surfaces A...

Страница 6: ...rating instructions and observe the safety instructions contained therein Take care of these operating instructions and keep them in a place where they can be accessed by everyone Untrained personnel...

Страница 7: ...the MaggHD vehicle in its magnetically shielded storage and shipping box when not in use Note Eddyfi strongly recommends using gloves when handling the vehicle to reduce magnetic pinching hazard Warni...

Страница 8: ...rwise damage may result Although designed for durability the vehicle and its components or attached devices may suffer structural damage if dropped or impacted A lifeline or fall arrest system should...

Страница 9: ...terline up to 60 m 200 ft deep or in dry environments It may also be used in non magnetic environments with removal of the magnet cups Typical applications include Underwater weld and paint inspection...

Страница 10: ...at 635 nm 1 5 mW Laser line separation is 70 mm 2 75 in CAUTION Class II Laser Do not intentionally stare into the beam Typically Class II relies on the blink reflex to limit exposure to no more than...

Страница 11: ...m Revision A08 Created by KJB Date 26 Sep 2019 3080885 A08 Source Location C ePDM ISLEng products au micromag manuals UMAU015088 docm Page 11 of 29 User Manual MaggHD Vehicle FIGURE 2 VEHICLE Dimensio...

Страница 12: ...inspection systems that are often pulled in and out of salt water aluminum anodes are especially important as zinc anodes tend to scale over when exposed to air and may not reactivate when submerged...

Страница 13: ...ted to 60 m 200 ft of water The tether connector and track connectors are dry mate types which must be dry when making a connection Keep the tether connector capped with a dummy plug when not connecte...

Страница 14: ...by KJB Date 26 Sep 2019 3080885 A08 Source Location C ePDM ISLEng products au micromag manuals UMAU015088 docm Page 14 of 29 User Manual FIGURE 4 MINI REEL Controller Connection Refer to controller us...

Страница 15: ...era onto the vehicle do the following removal is the reverse of installation 1 Make sure the starboard axle screw is fully disengaged tip should be slightly recessed in round housing 2 Slide the camer...

Страница 16: ...p 2019 3080885 A08 Source Location C ePDM ISLEng products au micromag manuals UMAU015088 docm Page 16 of 29 User Manual Pole Mounting Mounting the camera onto the optional inspection pole is nearly id...

Страница 17: ...magnet cups utilize rare earth permanent magnets and cannot be disabled or turned off The inspection surface must be carbon steel or alloy steel that has good magnetic properties Most structural steel...

Страница 18: ...assis plate using four groups of 8mm and 4 5mm spacers two groups per track The vehicle comes with a kit of spacers to accommodate a wide range of track spacing Use the following mounting hardware dep...

Страница 19: ...Fall Arrest IMPORTANT A lifeline or fall arrest system should always be used when vehicle detachment from the working surface threatens injury to personnel or damage to equipment A fall arrest system...

Страница 20: ...relief if applicable to your system Regularly inspect the tether for damage Regularly clean the tether Note Protecting the conductors inside the tether is critical to the life and operation of the tet...

Страница 21: ...rings with Molykote 111 or equivalent Use dust caps to protect connectors wherever possible Clean connectors with soap and fresh water rinse out with alcohol and allow connector to air dry before usi...

Страница 22: ...lights Test track control Test camera control Post Operations Check A Post Ops inspection should be carried out after every deployment using the following checklist Inspect the tether for damage as it...

Страница 23: ...e camera controls ICON Manual Control Interface and Recording ICON RPT Manual Reporting Playback and Video Export Driving the Vehicle When driving the vehicle the operator should always be conscious o...

Страница 24: ...age If a fuse blows stop and look for possible causes Causes might include cable damage water incursion or improper connections Fuse values have been carefully selected for their application Always re...

Страница 25: ...kground Interface box is not turned on Video cables are not hooked up between interface box and computer Camera connector on vehicle is loose turn power off first before plugging in camera Check monit...

Страница 26: ...er o If no current is registered then power or communication is not getting to the tracks Check all the cable connections Try power cycling the system Inspect the vehicle wiring for damage Check all t...

Страница 27: ...fice When ordering parts always make sure to quote the sales order acknowledgement SOA number and or the serial number of the system component in question Inuktun Services Ltd Canadian Headquarters an...

Страница 28: ...and customs instructions Items shipped without an RMA number will be held at Eddyfi Technologies until the correct paperwork is completed If cross border shipments are not labelled as per the instruc...

Страница 29: ...ed AC receptacles 5 Track belts tethers view ports and other components subject to wear through abrasion are warranted to be free from defects in material and workmanship for a period of ninety 90 day...