11
USING
THE C
ONTR
OL SY
STEM
Shows the water
temperature which the
burner tries to maintain.
Shows the water
temperature which
the burner tries to
maintain.
Adjusts the feed rela-
tive to the distribu-
tor's setting. If the
parameter is set to
10%, 10% more fuel
than the basic setting
will be fed in.
Shows how long the
burner will run between
each stop time. If the
value is 0, the burner
will go out completely
and must then be
started with the ignition
element or manually.
Shows the time
between each feed in
pause mode.
Shows how long the
fan will run after the
feed has stopped.
Shows how long the
external motor will
run each time the
internal fuel store is
emptied.
Starts the external
feed without the
burner operating.
Only the external
feed runs.
Shows how long be-
fore the external feed
will run, if it is started
as shown above.
The value which the
optical sensor must
exceed for the burner
to identify that the
pellets are burning.
A low value means that
no light is reaching
the receiver. (There are
pellets in the burner).
A value greater than 94
means that the burner
is emitting light. (There
are no pellets.)
Shows the value that
the optical sensor
records when it
detects the fl ames.
During operation this
will rise above 300.
Shows the value that the
level sensor must exceed
for the system to identify
that the store is empty.
Temperature menu
u
Oper. temp.
73°C
Operating menu
u
Oper. temp.
73°C
Adjust feed
0%
Pause menu
u
Run time
0.0s
Stop time
20m
Post-run time
30s
External feed
u
Run time ext.
30s
Start external
No
Manual time
1m
Sensors
u
Optical req.
30
Optical actual
XXX
Level req.
78
Level actual
XXX
Содержание BioLine 20
Страница 23: ...23 WIRING TABLE CONTROL CABINET...
Страница 24: ...24 OPERATING NOTES OPERATING NOTES Date Measure...
Страница 25: ...25 OPERATING NOTES OPERATING NOTES Date Measure...
Страница 26: ...26 OPERATING NOTES OPERATING NOTES Date Measure...
Страница 27: ...27 OPERATING NOTES OPERATING NOTES Date Measure...