INSTRUCTION MANUAL ECOSOFT
®
MEDIA SYSTEMS
38
Model range
Model
Overall dimensions,
m
(width × depth × height)
Nominal flow rate, m
3
/h
Quantity of media, L
Consumption of water
per regeneration, m
3
Required flow capacity
,
m
3
/h
1
FP-1054
0,3×0,3×1,6
0,6
28,3
0,3-0,5
1,2
FP-1252
0,4×0,4×1,6
0,9
56,6
0,5-0,7
1,7
FP-1354
0,4×0,4×1,6
1,0
56,6
0,5-0,8
2,0
FP-1465
0,4×0,4×1,9
1,2
84,9
0,6-0,9
2,3
FP-1665
0,5×0,5×1,9
1,6
113,2
0,8-1,2
3,0
1
supply water flow rate required for proper regeneration of system
9.5. Ecosoft FP media filtration systems
Requirements and limitations
Installation room
Ambient temperature
+5°C…+40°C
Relative humidity
≤80%
Operating environment
indoor; free of corrosive vapors, airborne
dust, and fibrous matter; sheltered from
weather and direct sunlight
Power supply
Electrical rating
230 V, 50 Hz (EU adapter)
Power
6 VA
Water supply
Pressure
2-6 bar (30-90 psi)
Water temperature
+4°C…+30°C
Prefilter rating
100 μm