27
INSTRUCTION MANUAL ECOSOFT
®
MEDIA SYSTEMS
To proceed, hold and
buttons
simultaneously for 3 seconds.
Enter hardness of influent water in ppm (parts
per million CaCO
3
).
If the control valve is equipped with internal
hard water mixing valve, there will be Service
Hardness entry (hardness of the mixed
product water) after influent water hardness.
Set Day Override (maximum number of days
in service, after which control valve will carry
out preventive regeneration). 14 days is
recommended.
Set the preferred time of delayed regeneration,
hours then minutes (factory set to 2 AM).
Press to exit the menu.
4.5. CT control valve setup
(
FP, FPA, FPC systems
)
After installing and powering up an Ecosoft FP, FPA, or FPC system, enter current time, and
regeneration options in the
Installer
menu of control valve.
Use
▲ and ▼ buttons to change setting;
SET
button to save and go to next step.
To proceed, hold SET and
▲ button
s for a few
seconds until Regeneration time screen shows up.
NORMAL MODE