INSTRUCTION MANUAL ECOSOFT
®
MEDIA SYSTEMS
32
9.1. Ecosoft FK Ecomix
®
systems
Requirements and limitations
Installation room
Ambient temperature
+5°C…+40°C
Relative humidity
≤80%
Operating environment
indoor; free of corrosive vapors, airborne
dust, and fibrous matter; sheltered from
weather and direct sunlight
Power supply
Electrical rating
230 V, 50 Hz (EU adapter)
Power
6 VA
Water supply
Pressure
2-6 bar (30-90 psi)
Water temperature
+4°C…+30°C
Prefilter rating
100 μm
Maximum influent concentrations
Hardness
750 mg/L CaCO
3
(
42 °dH; 45 gpg)
Iron
15 mg/L
Manganese
3 mg/L
Ammonia
4 mg/L
Chemical oxygen demand
20 mg/L O
2
Total dissolved solids
4000 mg/L