For ScaleGard
®
Pro Models
INSTR4158 0103
Installation and
Operating Instructions
Installation Precautions
• The filter must be installed with the inlet and outlet as
labeled. Make sure not to reverse connections.
• Do not install on hot water line. Maximum temperature
allowed is 100°F (38°C).
• Do not install on line pressure above 125 psi (862 kPa).
• Do not use wicking or sealer for fitting connections
into head of filter. Use Teflon
®
tape for connections.
• Do not use torch or other high temperature sources
near filter or plastic cartridge.
• Do not install near electric wires or water pipes which
will be in the path of drill when selecting the position
to mount the bracket.
• Do not install in direct sunlight.
• Protect from freezing. Drain filter when room temperature
drops to below 40°F (4.4°C).
• Allow minimum of 2” (5 cm) clearance space under
filter to facilitate cartridge change.
• Mount filter in such a position as to prevent it from
being struck by other items.
• Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection
before or after the system.
• Installation must comply with local and state plumbing
codes.
ScaleGard
®
Pro Scale Reduction Systems
SGP-124B, SGP-124BV, SGP-124S & SGP-124SV
consists of a mounting bracket, screws, head, and one cartridge.
SGP-248B & SGP-248S
consists of a mounting bracket, manifold, and two cartridges.
Teflon is a registered trademark of E.I. DuPont.
Dual Systems:
SGP-248B
SGP-248S
Single Systems:
SGP-124B
SGP-124BV
SGP-124S
SGP-124SV