Use the UP key to
select ON to turn on
smart recovery or
the DOWN key to
select OF to turn
smart recovery off.
Smart recovery initiates a heating or cooling call
so that the space is at temperature when the
setback period ends.
Option
Use the UP/DOWN
keys to select the
heating temperature
when the space is
vacant.
Option
Use the
keys to select the
cooling temperature
when the space is
vacant.
UP/DOWN
Option
Cool
Vacant
Vacant
Heat
12 Vacant Cooling Setpoint
11 Vacant Heating Setpoint
o
o
Range: 44 F to 75 F
o
Factory Default: 65 F.
10 Smart Recovery
Factory Default: Off. Range: On or Off.
Use the UP/DOWN
keys to change the
minimum off time
(minutes) before
restarting the
compressor.
Option
Option
Use the UP/DOWN
keys to change the
minimum off time
(minutes) before
restarting a gas
furnace or electric
strip heater.
06 Compressor Minimum Off Time
Factory Default: 2 Min. Range: 0 to 9 Min.
07 Heating Minimum Off Time
Factory Default: 0 Min. Range: 0 to 9 Min.
NEXT
ENTER
NEXT
ENTER
NEXT
ENTER
NEXT
ENTER
NEXT
ENTER
o
o
Range: 74 F to 95 F
o
Factory Default: 80 F.
Option
Use the UP key to
select “EL” for electric
operation where the
thermostat activates
the indoor fan (G
terminal) during
05 Setting the Fan Operation
Factory Default: Gas. Range: GA or EL
(Only displayed if Gas/Electric equipment,
GE, is selected in Option 01)
Touch NEXT or ENTER.
NEXT
ENTER
heating calls or DOWN key to select GA for gas
operation where the equipment plenum sensor
activates the indoor fan in heating calls.
Touch NEXT or ENTER.
Touch NEXT or ENTER.
Touch NEXT or ENTER.
Touch NEXT or ENTER.
Touch NEXT or ENTER.
Use the UP/DOWN
keys to set 0 or 1
stage.
Touch NEXT or
ENTER.
Option
03 Setting the Compressor Stages
This option is used to set the number of
compressor stages.
Factory Default: 1 . Range: 0 or 1
NEXT
ENTER
Option
Use the UP/DOWN
keys to set 0, 1 or 2
stage.
Touch NEXT or
ENTER.
Factory Default: 1 Stage. Range: 0, 1 or 2
04 Setting the Heating Stages
NEXT
ENTER
Use the UP/DOWN
keys to select 0, 1,
2.
Touch NEXT or
ENTER.
Option
Differential Mode0
Differential Mode1
Differential Mode2
o
0.5 On/Off Span.
o
1.0 On/Off Span.
o
1.5 On/Off Span.
09 Setting On-Off Temp Differential
Factory Default: #1. Range: 0, 1 or 2.
Option
Use the UP/DOWN
keys to change the
minimum run time
(minutes) before
turning a system off.
08 Minimum Run Time
Factory Default: 2 Min. Range: 0 to 9 Min.
NEXT
ENTER
NEXT
ENTER
Touch NEXT or ENTER.
INSTALLER SECTION
Use the
keys to set the time
in minutes to update
the sleeping and
living area airflow.
UP/DOWN
Option
This is the frequency, in minutes, that the damper
position is updated.
15 Airflow Update Time
Factory Default: 2 Min. Range: 1 to 20 Min.
NEXT
ENTER
Touch NEXT or ENTER.
Option
Night
Use the
key to
turn the low level
UP
The LCD has a low
level backlight that
can be used as a
night light.
16 Night Level LCD Backlight
Factory Default: On. Range: On or Off.
NEXT
ENTER
backlight ON or touch the
key to turn
OFF.
DOWN
Use the
key to
select ON for airflow
control or touch the
key to select
OFF to disable
airflow control.
UP
DOWN
Sleeping
Living
Airflow %
Option
This option turns the automatic airflow control on
or off. If off, the dampers fully open, nighttime
airflow options are disabled and airflow is no
longer displayed on the thermostat.
17 Airflow Control, On or Off
Factory Default: On. Range: On or Off.
NEXT
ENTER
If Airflow Control was off and is now being turned on,
the Nighttime Airflow option can be turned on using the
User Options.
Touch NEXT or ENTER.
Use the UP/DOWN
keys to change the
Living area
temperature to the
temperature that the
user feels is correct.
Living
Option
13 Calibrate Living Area Temperature Sensor
Factory Default: None.
Use the UP/DOWN
keys to change the
Sleeping area
temperature to the
temperature that the
user feels is correct.
Sleeping
Option
14 Calibrate Sleeping Area Temperature Sensor
NEXT
ENTER
o
Range - +/-5
NEXT
ENTER
Factory Default: None.
o
Range - +/-5
Touch NEXT or ENTER.
Touch NEXT or ENTER.
Touch NEXT or ENTER.
Page 7 of 16