WIRING DIAGRAM
TEMPERATURE SENSOR WIRING
Place wire between brass washer
and the printed circuit board and
hand tighten screw.
The TS5 sensor can be installed
in a single gang box or directly
to the wall using the hardware
provided.
HAND
TIGHTEN
Printed circuit board
Brass washer
Use 2-conductor, 18 or 20 gage, thermostat cable to wire from
the C365T21WF Thermostat to the temperature sensor in the
sleeping space.
Thermistor
Thermistor
Function
Sensor
Terminal
SNR
SNR
Wire Color
White
Red
C365
Terminal
TS
TS
i
Single Sensor Installation
Use one (1) Model TS510W sensor.
i
Dual Sensor Installation
Use two (2) Model TS520W sensors.
Warning!
!
Turn the power to the HVAC equipment off before wiring.
INSTALLER SECTION
R
COM
CLS
OPN
COM
CLS
OPN
C
W/OB
EQUIPMENT
Sleeping
Living
Y1
G
W2E/Y2
TS
Model A80-MT
Damper Actuator
Modulating or
Open/Close
24VAC,2.4VA
COM
OPN
CLS
Made in USA
eControls, Inc.
Model A80-MT
Damper Actuator
Modulating or
Open/Close
24VAC,2.4VA
COM
OPN
CLS
Made in USA
eControls, Inc.
G
G
W2
Y2
GE HP
E
Y2
HVAC System
Model R80CT-XX
Sleeping Space
Damper
Model C365T21WF
Thermostat (in living area)
Model R80CT-XX
Living Space Damper
Y
Y
W O or B
C
C
R
R
C365T21WF
TS
Model TS510W (one)
Temperature Sensor
for Sleeping Area
Model TS520W (two)
Temperature Sensors
for Sleeping Area
(temperatures are
averaged)
-OR-