I M P O R T A N T !

Please read all instructions carefully before

beginning installation and save for future reference.

Before removing any wiring from your existing thermostat, its wires

must be labeled with their terminal designations.

Ignore the color of the wires since they may not comply with any standard.

Thank you for your confidence in our product. To obtain the best results from

your investment, please read this manual and acquaint yourself with your
purchase before installing your new thermostat. Then follow the installation
procedures, one step at a time. This will save you time and minimize the chance
of damaging the thermostat and the systems it controls. These instructions may
contain information beyond that required for your particular installation. Please
save for future reference.

PSDH121 SERIES

DIGITAL ELECTRONIC HEAT PUMP THERMOSTAT

HEAT

OFF

COOL

MO

Set Temperature

Choose Heat or Cool

Installs Easily

Easy as

1–2–3

Complete, Easy To Read

INSTALLATION AND OPERATING INSTRUCTIONS

COMPATIBILITY

LUX PSDH121 was designed

for use with single stage heat
pump systems with auxiliary
and/or emergency heat. These
systems are typical known as
2-stage heat one stage cool heat
pump systems.

FEATURES

Slim design may be vertically or horizontally
mounted

Large easy to read backlit display

Fan switch for system or continuous fan 
operation

Emergency Heat Switch

Simple temperature Up or Down keys will 
display and adjust the Set Temperature.

Temperature displays in F° or C°

Temperature differential SWING settings of 
0.25 and 0.5

Selectable 2 or 5-Minute Minimum Run/Off time provides short cycle and 
compressor protection

TEMP UP

MODE

FAN

MODE

TEMP DOWN

BACKLIGHT

RESET

WARNING:

Use Energizer

®

or DURACELL

®

Alkaline Batteries Only.

Energizer

®

is a registered trademark of Eveready Battery Company, Inc.

DURACELL

®

is a registered trademark of The Gillette Company, Inc.

In the winter, set the system switch to HEAT to control your system while 
heating.

In the summer, set the switch to COOL to control your system while cooling.

Press the TEMPERATURE UP or DOWN key in order to show the
current 

SET TEMPERATURE

.

Press 

TEMPERATURE UP

or 

DOWN

keys again until your desired

temperature is displayed. The display will show the current room temperature
again after two seconds.

Press the light bulb button to illuminate the display. Adjusting the temperature

will keep the display lit until no button has been pressed for over ten seconds.

In spring and fall or when windows are open, you can set the system switch

to 

OFF

.

Setting the 

FAN

switch to 

AUTO

automatically runs your system’s fan during

heating and cooling.

Setting the 

FAN

switch to 

ON

runs your system’s fan continuously even

without heating or cooling.

Setting the Mode switch to 

EMER

(emergency heat) runs your Emergency

heating system rather than the heat pump.

N O T E

The FAN switch works only if your system provides a wire for a thermostat’s “G” terminal.

INSTALLATION

Please read all instructions carefully before beginning installation.

C A U T I O N

*** Turn off electricity to the appliance before installing or

servicing thermostat or any part of the system. Do not turn
electricity back on until work is completed. ***

Do not short (jumper) across electric terminals at control on furnace or air 
conditioner to test the system. This will damage the thermostat and void 
your warranty.

All wiring must conform to local codes and ordinances.

This thermostat is designed for use with 24 volt systems. The thermostat 
should be limited to a maximum of 1.5 amps; higher current may cause
damage to the thermostat. If you are in doubt, call your HVAC contractor.

Your thermostat is a precision instrument. Please handle it with care.

OFF

TOOLS REQUIRED

#1 Phillips screwdriver (small)

Drill with 3/16-in. (4.8mm) bit

Wire stripper/cutter

THERMOSTAT LOCATION

On replacement installations, mount the new thermostat in place of the old

one unless the conditions listed below suggest otherwise. On new installations,
follow the guidelines listed below.

Remember that your PSDH121 may be mounted vertically or horizontally 
when determining the optimal location.

Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, 
and in a room that is used often.

Do not install it where there are unusual heating conditions, such as: in direct 
sunlight; near a lamp, radio, television, radiator, register, or fireplace; near hot 
water pipes in a wall; near a stove on the other side of a wall.

Do not locate in unusual cooling conditions, such as: on a wall separating an 
unheated room; or in a draft from a stairwell, door, or window.

Do not locate in a damp area. This can lead to corrosion that will shorten 
thermostat life.

Do not locate where air circulation is poor, such as: in a corner or an alcove; 
or behind an open door.

Do not install the unit until all construction work and painting has been
completed.

OPERATING INSTRUCTIONS