Installer and User Manual
Model C365T21WF
365
Comfort
Ver4.06 / Ver1.0.4 Sep 2018
Model A80WL2
Damper Actuator
Wireless
24VAC,2.8VA
24VAC
24VAC
Made in USA
eControls, Inc.
Model A80WL2
Damper Actuator
Wireless
24VAC,2.8VA
24VAC
24VAC
Made in USA
eControls, Inc.
Pat. Pending
365
Comfort
Wi
Fi
Living
Tu
Day
Sleeping
Living
Airflow %
COOL
Schedule
AUTO
FAN
MENU
MODE
Cool
Set To
SYSTEM
AM
WiFi
DESCRIPTION
Off, Heat, Cool and Auto
System Modes
Thermostat Modes
Hold, Schedule or Vacant mode.
Programs Per Day
Morning, Daytime, Evening and Night.
Program Format
Weekdays and weekend– 5/2.
Temperature Override
Temperature is held for 3 hours when adjusted in Schedule
mode.
Fan Modes
Auto or Continuous (On)
Airflow Control
Airflow control can be turned off using Option 17. The
thermostat will operate as a typical thermostat.
Compatible Equipment
Gas/electric equipment with 2-stage heating and 1-stage
cooling or 1-stage heating and 2-stage cooling and heat
pumps with 2-stage heating and 2-stage cooling.
Wired Sleeping Area Temperature Sensors
One TS510W sensor or two TS520W sensors can be used in the
sleeping space and wire to the thermostat.
Modulating Dampers
Round or rectangular dampers using the A80MT wired actuator
and up to 1 inch static pressure.
Power
Operates on 24VAC from the HVAC equipment using the R and
C wires.
The Comfort365 thermostat controls heating, cooling and
airflow to the sleeping and living spaces. The thermostat is
installed in the living space, a temperature sensor is
installed in the bedroom space and two modulating
dampers are installed to control the airflow to the living and
sleeping space.
The C365 thermostat monitors the temperature at the
sensor and the temperature at the thermostat every 2
minutes during heating and cooling calls. If the
temperatures are different, the Comfort365 automatically
adjusts the modulating dampers 2% so that more airflow is
directed to the space that needs it for a uniformly
comfortable home.
Nighttime Operation
At night, the C365 thermostat uses the temperature sensor in
the sleeping space to control heating and cooling calls and
directs more airflow to the sleeping space and less airflow to the
unoccupied living space. Energy savings is 30% at night.
If
bedrooms are located downstairs, consider turning off the
Nighttime Airflow Control option off.
Remotely access the home’s HVAC system from anywhere using
a smart phone, tablet or PC.
Remote Access
FEATURES
Airflow Limits
Maximum airflow limits in heating and cooling can be set
during installation.
Manual Airflow Control
Manual airflow control enables the homeowner to direct more
airflow to the living or sleeping space as they desire. This option
is ideal for homeowners who have an unusual work schedule,
home office or spend more time in one space than the other.