4. Gas analysis
4.1. Measurement preparation
Prepare the instrument for operation in that you perform all connec-
tions (T-Room sensor and T-Gas, GAS and DRA of the 3-chamber
hose). Make sure that:
- the condensate pad has enough absorption capability
(condensate trap with monitoring)
- the condensate receptacle contains no humidity
(condensate trap without monitoring)
- the fine dust filter and the safety filter are not soiled
darker than number 3 on the soot scale
4.2. Gas analysis
Once the 1-minute calibration phase is over, the instrument enters
the measurement mode. The values are viewable on 4 screen pages
(3 x gas analysis; 1 x CO measurement; use the cursor keys to scroll
the pages):
1. Always position the probe in the exhaust pipe
once the calibration phase is over!
2. Never operate the instrument in the transport
case (recommended for transport)!
To obtain accurate measurement values, re-calibrate
the instrument after each measurement
(at the latest after one hour)!
O2
4.0
%
CO2
12.5
%
CO
30
ppm
Lambda
1.23
T.Gas
166
°C
T.Air
20
°C
Losses
7.0
%
Eta
93.0
%
O2
4.0
%
CO2
12.5
%
T.Air
20
°C
T.Gas
212
°C
O2
4.0
%
CO2
12.5
%
CO
30
ppm
Lambda
1.23
Always use a filtering system as per our
recommendation for combustion plants
firing solid combustibles!